![UNIT INTRODUCTION](/images/new-backgrounds/33388/333885x1.webp)
UNIT INTRODUCTION
This 577D unit is a small packaged gas heat/electric cooling system that can utilize the comfort of gas heating packaged along with effi- cient electric air conditioning. This unit uses Puron®, the environ- mentally friendly refrigerant, for cooling.
OPERATING YOUR UNIT
The operation of your unit is controlled by the Evolutiont User In- terface (UI). You simply program the UI and it maintains the indoor temperature at the level you select. See UI manual for detailed in- structions.
To better protect your investment and to eliminate unnecessary ser- vice calls, familiarize yourself with the following facts:
To start unit gas heat:
Refer to Fig. 2 for location of unit front access panel. Refer to Fig. 3 for location of gas valve. Refer to Fig. 4 while proceeding with the following steps.
1.Set the temperature selector on UI to the lowest temperature setting and set system switch to HEAT.
2.Close the external manual gas shutoff valve.
3.Turn off the electrical supply to the unit.
4.Remove the front access panel with a
5.Move the selector switch on the internal gas valve to the OFF position and wait 5 minutes.
6.Move the selector switch on the internal gas valve to the ON position.
7.Replace the front access panel.
8.Turn on the electrical supply to unit.
9.Open the external manual gas shutoff valve.
10.Set the temperature selector on UI slightly above room tem- perature to start unit. The
11.Set the temperature selector on UI to desired setting.
Filter Access Panel
For Accessory Filter Rack
Access Panels
A09045
Fig. 2 - Accessory Filter Rack Access Panel
Flue Hood
Burners Gas Valve
A09043
Fig. 3 - Gas Heating/Electric Cooling Unit with Access Panel Removed (Standard unit shown. Actual appearance is shown in Fig. 2.)
!WARNING
FIRE AND EXPLOSION HAZARD
Failure to follow this warning could result in personal injury, death, and/or property damage.
1.If the main burners fail to light, or the blower fails to start, shut down gas heating section and call your dealer for service.
2.Never attempt to manually light the main burners on unit with a match, lighter, or any other flame. If the electric sparking device fails to light the main burners, refer to the following shutdown procedures, then call your dealer as soon as possible.
To shut off unit gas heat:
!WARNING
FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury, death, and/or property damage.
Do not turn off the electrical power to unit without first turning off the gas supply.
Note:If the unit is being shut down because of a malfunction, call your dealer as soon as possible.
Should overheating occur or the gas supply fail to shut off, shut off the external manual gas valve to the unit before shutting off the elec- trical supply. Do not use this unit if any part has been under water. Immediately call a qualified service technician to inspect the unit and to replace any part of the control system and any gas control which has been under water.
Refer to Fig. 4 while proceeding with the following steps.
1.Set the temperature selector on UI to lowest temperature set- ting and set system SWITCH to OFF.
2.Close the external manual shutoff valve.
3.Turn off the electrical power supply to the unit.
4.Remove the front access panel.
5.Move the selector switch on the internal gas valve to the OFF position.
To start unit electric cooling:
Refer to Fig. 5 while proceeding with the following steps.
1.Set the temperature selector on UI to highest temperature setting and set system SWITCH to OFF.
2.Close the external manual shutoff valve.
3.Turn off the electrical power supply to the unit.
3