SAFETY CONSIDERATIONS
Installation and servicing of this equipment can be hazardous due to mechanical and electrical components. Only trained and qualified personnel should install, repair, or service this equipment.
Untrained personnel can perform basic maintenance functions such as cleaning and replacing air filters. All other operations must be performed by trained service personnel. When working on this equipment, observe precautions in the literature, on tags, and on la- bels attached to or shipped with the unit and other safety precautions that may apply.
Follow all safety codes. Installation must be in compliance with lo- cal and national building codes. Wear safety glasses, protective clothing, and work gloves. Have fire extinguisher available. Read these instructions thoroughly and follow all warnings or cautions included in literature and attached to the unit.
Recognize safety information. This is the
Note: Installer: This manual should be left with the equipment user.
!CAUTION
FOR YOUR SAFETY
Failure to follow this caution may result in personal injury.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
!WARNING
FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury, death or property damage.
Do not use this unit if any part has been underwater. Immediately call a qualified service technician to inspect the unit and to replace any part of the control system which has been underwater.
!WARNING
For your safety if you smell gas:
1.Do not try to light any appliance.
2.Do not touch any electrical switch; do not use any phone in your building.
3.Immediately call your gas supplier from a nearby phone. Follow the gas supplier’s instructions.
4.If you cannot reach your gas supplier, call the fire department.
UNIT INTRODUCTION
This 677B unit is a small packaged Hybrid Heatt system that can utilize both the efficiency of heat pump heating and the comfort of gas heating. The system will optimize for ideal heating, depending on several factors. This unit uses Puron→, the ozone friendly refrig- erant, for cooling and heat pump heating.
You may notice your
!WARNING
FIRE, EXPLOSION HAZARD
Failure to follow this warning could result in death, personal injury and/or property damage.
Do not attempt to light by hand.
!WARNING
FIRE, EXPLISION, ELECTRICAL SHOCK HAZARD
Failure to follow this hazard warning could result in personal injury, death and/or property damage.
1.Do not turn off the electrical power to unit without first turning off the gas supply.
2.Before attempting to start the gas heating section, familiarize yourself with all the procedures that must be followed.
Starting or Shutting Off Unit
To start the unit:
1.Turn on the electrical power supply to unit.
2.Turn on the gas supply to unit.
3.Select temperature and set User Interface (UI) control to desired mode.
To shut off unit:
Note: If the unit is being shut down because of a malfunction, call your dealer as soon as possible.
1.Set UI control to OFF.
2.Turn off gas supply to unit.
3.Turn off electrical power supply to unit.
OPERATING YOUR UNIT
The operation of your unit is controlled by the Evolutiont UI. You simply program the UI and it maintains the indoor temperature at the level you select. See UI manual for detailed instructions.
To better protect your investment and to eliminate unnecessary ser- vice calls, familiarize yourself with the following facts:
Step 1—Cooling Mode
With the SYSTEM control set to COOL, your unit will run in cool- ing mode until the indoor temperature is lowered to the level you have selected. On extremely hot days, your unit will run for longer periods at a time and have shorter “off” periods than on moderate days.
Step 2—Hybrid Heating Mode
Your Hybrid Heat system combines the strengths of two heating sources; an electric heat pump and a gas furnace. A Hybrid Heat system provides more control over your monthly energy bills by al- lowing you to choose the most economical method of heating. As conditions change, the system automatically switches between the two sources to maintain greater efficiency than with a