CONTROL FEATURES
CONTROL | FAN SPEED | DEHUMIDISTAT | CONTINUOUS | INTERMITTENT |
DESCRIPTION | CONTROL | CONTROL | MODE | MODE |
|
|
|
|
|
OneTouch | Yes | No | Yes | Yes |
Basic | Yes | No | Yes | No |
|
|
|
|
|
Standard | Yes | Yes | Yes | Yes |
|
|
|
|
|
Basic Control:
Allows the user to manually set fan speed to low or high as required to maximize comfort.
Standard Control:
Offers automatic dehumidistat control and the option to select continuous or intermittent fan operation. Setting the wall control to low will activate the continuous mode.
OneTouch Control:
Allows control of ventilator with the touch of a button. This control will operate as a main wall control. The OneTouch will operate the unit in Intermittent Mode (20 minutes per hour), continuous low speed, continuous high speed, and off.
AUTOMATIC DEFROST CYCLE FEATURES
All models offer a
| 25_F TO 55_F |
| 17_F |
| BELOW | |||||
MODEL | 15_C) | ---( 27.8_C) | ||||||||
|
|
|
|
|
|
|
|
|
| |
| DEFROST* |
| EXCHANGE{ | DEFROST* |
| EXCHANGE{ | DEFROST* | EXCHANGE{ | ||
|
|
|
|
|
|
|
|
|
|
|
ERVBBLHA | 6 Minutes |
| 60 | Minutes | 6 Minutes |
| 32 | Minutes | 6 Minutes | 20 Minutes |
|
|
|
|
|
|
|
|
|
|
|
HRVBBLHA | 6 Minutes |
| 60 | Minutes | 6 Minutes |
| 32 | Minutes | 6 Minutes | 20 Minutes |
|
|
|
|
|
|
|
|
|
|
|
*All defrost times are in the standard mode (as shipped)
{Time between defrost when within specified temperature range
ERV / HRV
5