temperature sensed by the working sensor every 10 seconds. The control will operate from the temperature sensed by the working sensor.

E1 − If the Display Module and the Equipment Control Module cannot communicate via two−wire connection, an E1 will be displayed.

E2 − There is no E2 error message.

E3 − If AC/HP Control cannot properly read outdoor temperature, and it is needed for proper operation, display will indicate “−−” in the outdoor temperature location.

E4 − If AC/HP Control’s internal memory fails, E4 will be displayed. Replace AC/HP Control.

Table 3 can be used as a troubleshooting tool for determining which outputs will be active for a particular configuration and each operating mode.

When replacing a failed component such as an equipment control module or a display module, the installer should replace both parts as a matched set. It is very easy to accidentally mix an A/C or HP display with a PAC equipment control module. When this happens, some functions appear in the setup while others do not. This can be very confusing to troubleshoot. Verify that both parts have the same model and serial number when troubleshooting the thermostat.

46

Page 48
Image 48
Bryant T6-PAC, T6-NAC, T6-NHP, T6-PHP installation instructions

T6-PAC, T6-NAC, T6-NHP, T6-PHP specifications

The Bryant T6 series is a line of advanced heating and cooling systems designed to offer exceptional comfort, energy efficiency, and cutting-edge technology for residential and commercial applications. The series includes models such as T6-PHP, T6-NHP, T6-NAC, and T6-PAC, each tailored to meet specific heating, ventilation, and air conditioning (HVAC) needs.

The Bryant T6-PHP (Heat Pump) model stands out with its dual-fuel capability, providing both electric heat pump operation and backup gas heating. This versatility allows for optimal energy use depending on outdoor temperatures, ensuring lower utility bills and consistent comfort. It also features high-efficiency ratings, making it an environmentally friendly choice, while its variable-speed compressor allows for quiet operation and precise temperature control. The T6-PHP is equipped with smart technology that allows homeowners to monitor and adjust settings remotely through mobile applications.

Similarly, the T6-NHP (Natural Gas Heat Pump) variant is designed for regions where natural gas is readily available. This model combines the efficiency of heat pump technology with the reliability of natural gas heating. The T6-NHP features intelligent performance diagnostics that help to optimize operation and reduce maintenance costs, ensuring that the system runs smoothly throughout its lifespan.

The T6-NAC (Air Conditioner) model focuses on delivering exceptional cooling performance. With enhanced energy efficiency ratings, it utilizes environmentally friendly refrigerants and is designed to reduce electricity consumption while providing consistent indoor comfort. The T6-NAC features advanced airflow technology that allows for better distribution of cooled air, improving overall comfort levels in the home.

Lastly, the T6-PAC (Packaged Air Conditioner) is a self-contained system that combines cooling and heating in a single unit, making it ideal for homes with limited installation space. This all-in-one unit features a compact design while still delivering high efficiency and performance. With a programmable thermostat and integration with smart home technology, the T6-PAC ensures user-friendly operation and convenient control.

In summary, the Bryant T6 series leverages state-of-the-art technology, energy-efficient designs, and user-friendly features to provide superior HVAC solutions. Whether it's the versatile heating capabilities of the T6-PHP and T6-NHP or the efficient cooling of the T6-NAC and T6-PAC, these units are engineered to deliver unmatched comfort and reliability for today's homeowners.