DRIP T I M E A/B: 15
BREWS TO EMPTY
Enabl EnergySavr
NO DONE YES
AIR PUMP POWER 4
BREW COUNT ##
NOYES
BREW COUNT ## RESET NEXT
CALIBRATE FLOW ?
NOYES
PRESS
BREW TO START
ENTER OZ 10.0
SERVICE TOOLS ?
NOYES
TEST OUTPUTS ?
NOYES
INDEX | B | MOTOR |
DUMP | NEXT | LOAD |
|
|
|
EXTERNAL RELAY
ON NEXT OFF
PROGRAM FUNCTIONS
DRIP TIME (A/B)
Time between brew cycle and pod ejection.
BREWS TO EMPTY
Set number of used pods in bin to turn on "EMPTY BIN" message.
ENABLE ENERGY SAVER
Choose to have the tank heaters turn off, or reduce the tank temp to (140° F) or (60° C) once the "SET IDLE TIME" has
AIR PUMP POWER (1 Weakest - 4 Strongest )
Adjust air pressure for end of brew cycle purge. Due to pod variations, reduce as needed if splattering occurs.
BREW COUNTS
Retains the total number of brew cycles completed, not
BREW COUNTS
Retains the total number of brew cycles completed,
CALIBRATE FLOW
This function allows you to enter the actual flow rate of the sprayhead by dispens- ing for one minute. The volume is then entered in ounces per minute. (Oz/M)
Place a 10 ounce or larger measuring cup under sprayhead and press one of the brew switches.
After dispense finishes, read number of ounces and enter that amount into brewer using the +/- switches, then press "DONE" to set the volume into memory.
SERVICE TOOLS allows testing of load components and switches.
It should only be used by trained technicians.
TEST OUTPUTS allows testing of load components by manually turning them
ON/OFF.
WARNING: HOT WATER WILL DISPENSE DURING SOME TEST MODES!
INDEX MOTOR DUMP runs the pod holder back to the pod ejection position. LOAD moves it out to the door open position. "B " indicates the assembly is in home postion.
EXTERNAL RELAY Main control board outputs 12vdc to activate external relay. The N.O. contact then closes to provide line voltage to the heater in HOT WATER TANK.
CONTINUED