Page 5
Models CWT & CWTF
PLUMBING REQUIREMENTS
These brewers must be connected to a cold water system with operating pressure between 20 and 90 psi
(138 and 620 kPa) from a 12" or larger supply line. A shut-off valve should be installed in the line before the
brewer. Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce it to 50 psi (345
kPa) . The water inlet fi tting is 38" fl are.
NOTE - Bunn-O-Matic recommends 38" copper tubing from the 12" water supply line. A tight coil of copper tubing
in the water line will facilitate moving the brewer to clean the countertop. Bunn-O-Matic does not recommend
the use of a saddle valve to install the brewer. The size and shape of the hole made in the supply line by this type
of device may restrict water fl ow.
This equipment must be installed to comply with the Basic Plumbing Code of the Building
Offi cials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation
Manual of the Food and Drug Administration (FDA). For models installed outside the U.S.A.,
you must comply with the applicable Plumbing/Sanitation codes for your area.
1. Remove cap from the fl ared fi tting on the bottom
of the center tube assembly.
2. Flush the water line and securely attach it to the
are fi tting on the center tube assembly.
3. Turn on the water supply.
4. On models with faucet place an empty vessel
beneath the faucet and lift the handle until water
is dispensed.
ON
OFF
T
A
N
K
This equipment is to be installed to
comply with the Basic Plumbing Code of
the Building Officials and Code
Administrators International, Inc. (BOCA)
and the Food Service Sanitation Manual
of the Food and Drug Administration (FDA).
Fill water tank before turning -on
thermostat or connecting appliance
to power source.
Do not use near combustibles.
Follow national/local electrical codes.
Electrically ground the chassis.
Use only on a properly protected
circuit capable of the rated load.
FAILURE TO COMPL
Y RISKS EQUIPMENT
DAMAGE, FIRE, OR SHOCK HAZARD
READ THE ENTIRE OPERA
TING MANUAL
INCLUDING THE LIMIT OF WARRANTY AND
LIABILITY BEFORE BUYING OR USING THIS PRODUCT
THIS APPLIANCE IS HEA
TED WHENEVER
CONNECTED TO A POWER SOURCE
00831.0000A 5/88 © 1988 BUNN-O-MATIC CORPORATION
WARNING
!
P1241
10737 081706