PROGRAMMING
When power is applied to the dispenser, the display located on the bottom of the main circuit board will show
the revision level of the software for 5 seconds, and then go to (-). While the tank is fi lling, the display will read
(FIL). When the tank is full the display will return to (-).
LEVEL 1 PROGRAMMING
TANK WATER TEMPERATURE & READY TEMPERATURE SET-UP
1. Press and hold the center button until P1 appears on the display (approximately 3
seconds) then release button. The tank water temperature set point will appear on
the display (Factory default is 90° F).
2. Use the (+) button to increase the temperature set point, and the (-) button to de-
crease the set point.
3. Press and release the center button once more. The display will read P2, then show
the ready temperature set point (Factory default is 85°F).
4. Use the (+) button to increase the temperature set point, and the (-) button to de-
crease the set point.
5. To exit Level 1 Program press and release the center button once more. The display
will read (-).
LEVEL 2 PROGRAMMING
DISPENSE TEMPERATURE LOCKOUT, FAHRENHEIT OR CENTIGRADE SELECTION, &
FACTORY DEFAULTS
1. Press and hold the center button until H1 appears on the display (approximately 6
seconds) then release button. The display will either read noL (LOCKOUT DISABLED)
or Loc (LOCKOUT ENABLED).
2. Use the (+) and (-) buttons to alternate between Loc and noL.