TROUBLESHOOTING (cont.) |
|
|
|
Problem | Probable Cause | Remedy | |
Water boils continuously. | 1. | Temperature control | Refer to Service – electronic controls for |
|
|
| testing procedures. |
| 2. | Lime | Inspect the tank assembliy for excess lime |
|
|
| deposits. Delime as required. |
CAUTION – Tanks and tank components should be delimed reglarly depending on local water conditions. Exces- sive mineral
Dispenser is making unusual 1. | Plumbing lines |
noises. |
|
3. | Water supply |
Ready indicator will not light. | 1. | Temperature control |
| 2. | Ready Indicator LED |
Plumbing lines should not be resting on the counter top.
(A)The dispenser must be connected to a cold water line.
(B)Water pressure to the dispenser must not be higher than 90 psi (620 kPa). Install a regulator if necessary to lower the work- ing pressure to approximately 50 psi (345 kPa).
Refer to Service – electronic controls for testing procedures.
Replace the indicator LED.
6 | 42311 071310 |
|