21

CALIBRATING THE DISPENSER (Cont.)

LCD DISPLAY CALIBRATION MODE DESCRIPTION
Right (Decaf) Water Rate Set PRIME-NORMAL-RINSE switch to
RINSE position. Press and hold Decaf
Dispense Switch until flow stops (20
sec.) Refer to Field Calibration of the
Concentrate Pumps.
MENU (-) (+)
C 4 r u n
Right (Decaf) Water Rate Enter Liters collected from the 20 sec.
test above.
Default = 1.08
Range = 0.95 - 1.20 Liters
MENU (-) (+)
C 4 1. 0 8
Pump “OFF” Delay Delays the Pump turn off after a
dispense.
Default = 200
Range = 1 - 999 mSec.
MENU (-) (+)
C 6 2 0 0
Reset Factory Defaults Resets all set up values to the Factory
Default setting.
Hold both Increase (+) and Decrease
(-) switch for 10 seconds.
MENU (-) (+)
C 9 - - -
Displays Software Version # -
Exits To Home View After 3 Seconds.
MENU (-) (+)
L C x x
English or Metric Mode Eng for English
S.I. for Metric
MENU (-) (+)
C 7 E n g
Error Code History Displays last known Error Code
Depress the Decrease (-) to view the
last 3 Errors.
Hold the Decrease (-) & Increase (+)
switches for 10 sec. to Erase.
MENU (-) (+)
C 8 - - -
38791 040306