Troubleshooting (Continued)

Screen Displayed

Possible Cause

Troubleshooting Procedures

COOL TEMP SENSOR OUT OF RANGE

CHECK FOR BAD CONNECTIONS

1.

C o r r e s p o n d i n g Te m p e r a t u r e

Service Required

 

Sensor Probe wire(s) broken or

 

 

disconnected.

 

2.

Product cabinet temperature too low.

Service Required

COOL TEMP SENSOR

1.

Corresponding Temperature Sensor

Service Required

OUT OF RANGE

 

Probe wire(s) shorted to housing, or

 

 

 

 

 

to each other.

 

CHECK WIRE FOR

2.

Product cabinet temperature too

Service Required

SHORTS

 

high.

 

 

 

 

 

 

 

EVAP TEMP SENSOR

1.

Corresponding Temperature Sensor

Service Required

OUT OF RANGE

 

Probe wire(s) broken or disconnected.

 

 

 

 

2.

Evaporator temperature too low.

Service Required

CHECK FOR BAD

CONNECTIONS

 

 

 

 

 

 

 

 

 

EVAP TEMP SENSOR

1.

Corresponding Temperature Sensor

Service Required

OUT OF RANGE

 

Probe wire(s) shorted to housing, or

 

 

 

 

 

to each other.

 

CHECK WIRE FOR

 

 

 

SHORTS

2.

Evaporator temperature too high.

Service Required

 

 

 

 

 

 

 

 

 

 

 

 

COOLER FAULT!

1.

Cabinet circulating fan failure

Service Required

EVAP TEMP TOO HI

2.

Ice build up on evaporator coils

Service Required

 

 

 

CHECK EVAP FAN

 

 

 

CHK EVAP SENSOR

3.

Evaporator sensor failure

Service Required

 

 

 

 

 

 

COOLING TIME

1.

Air intake filter clogged

Clean Air Filter

TOO LONG

2.

Wiring failure

Check wiring harness for breaks,

 

 

 

CHECK

AIR FILTER

 

 

shorts, open connectors

CHECK COOLING UNIT

3.

Compressor failure

Service Required

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COND PROBE FAULT

1.

Tube leaking

Check pump & tubing for

CHECK COND PROBES

 

 

proper installation

 

 

 

2.

Dispense switch failure

Service Required

CHK DISP SWITCHES

3.

Dispense valve leaking

Service Required

CHK CONNECTIONS

 

 

 

 

 

 

 

 

JUMPER FAULT!

1. Invalid wire harness configuation

Service Required

CONFIG NOT VALID

 

 

 

CHECK J-18

ON CONTROL BOARD

29