Troubleshooting (Continued)
Screen Displayed |
| Possible Cause |
| Troubleshooting Procedures | ||||
|
|
|
|
| ||||
LEFT BIB EMPTY! | 1. | Concentrate BIB is Empty. |
| Replace BIB, see loading the | ||||
|
|
|
|
|
|
| Concentrate | |
REPLACE PRODUCT | 2. | BIB Not properly connected. |
| Check BIB Connector Fittings | ||||
3. | Tubing kinked or blocked. |
| Check Tubing installation | |||||
CHECK THRESHOLD |
| |||||||
4. | Empty BIB Warning set too high. | Check Threshold, see Field Cali- | ||||||
|
|
|
| |||||
|
|
|
|
|
|
| brating the Empty BIB Warning | |
|
|
|
|
| ||||
|
|
|
|
| ||||
RIGHT BIB EMPTY! | 1. | Concentrate BIB is Empty. |
| Replace BIB, see loading the | ||||
|
|
|
|
|
|
| Concentrate | |
REPLACE PRODUCT | 2. | BIB Not properly connected. |
| Check BIB Connector Fittings | ||||
3. | Tubing kinked or blocked. |
| Check Tubing installation | |||||
CHECK THRESHOLD |
| |||||||
4. | Empty BIB Warning set too high. | Check Threshold, see Field Cali- | ||||||
|
|
|
| |||||
|
|
|
|
|
|
| brating the Empty BIB Warning | |
|
|
|
|
|
|
|
| |
OVERFLOW CUP | 1. | Refill valve stuck open |
| Service Required | ||||
FULL. EMPTY CUP | 2. | Faulty refill probe |
| Service Required | ||||
|
|
|
|
| ||||
|
|
|
| 3. | Faulty overflow switch |
| Service Required | |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
HEATING TIME TOO | 1. | Tank Heater failure |
| Service Required | ||||
LONG | 2. | Triac failure |
| Service Required | ||||
|
|
|
|
| ||||
CHECK HEATING |
|
|
|
| ||||
CIRCUIT | 3. | Tank Temp. sensor failure |
| Service Required | ||||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
FILL TIME TOO LONG | 1. | Water shut off to dispenser |
| Check water supply | ||||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| ||
CHECK WATER SUPPLY | 2. | Inlet Solenoid Valve failure |
| Service Required | ||||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
TANK TEMP SENSOR | 1. | Corresponding Temperature | Sensor | Service Required | ||||
OUT OF RANGE |
| Probe wire(s) broken or disconnected |
| |||||
CHECK |
|
|
|
|
|
|
| |
FOR BAD |
|
|
|
| ||||
CONNECTIONS |
|
|
|
| ||||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| ||
TANK TEMP SENSOR | 1. | Corresponding Temperature | Sensor | Service Required | ||||
OUT OF RANGE |
| Probe wire(s) shorted to housing, or to |
| |||||
CHECK |
|
|
| each other. |
|
| ||
WIRE FOR |
|
|
|
| ||||
SHORTS |
|
|
|
| ||||
|
|
|
|
|
|
|
|