Troubleshooting (Continued)
Left Refill LED “ON” | Concentrate BIB is Empty. | Replace BIB, see Loading the Concentrate |
Left BIB Empty | BIB Not properly connected | Check BIB Connector Fittings |
| Tubing kinked or blocked | Check Tubing Installation |
| Empty BIB warning set too high | Check Threshold, see Field Calibrating the |
|
| Emoty BIB Warning |
|
|
|
|
|
|
Right Refill LED “ON” | Concentrate BIB is Empty. | Replace BIB, see Loading the Concentrate |
Right BIB Empty | BIB Not properly connected | Check BIB Connector Fittings |
| Tubing kinked or blocked | Check Tubing Installation |
| Empty BIB Warning set too high | Check Threshold, see Field Calibrating the |
|
| Empty BIB Warning |
|
|
|
|
|
|
Left Refill LED | Left Dispenser will not operate | Replace BIB, see loading the Concentrate |
“FLASHING” |
|
|
Empty BIB Lockout |
|
|
Enabled |
|
|
|
|
|
|
|
|
Right Refill LED | Right Dispenser will not operate | Replace BIB, see loading the Concentrate |
“FLASHING” |
|
|
Empty BIB Lockout |
|
|
Enabled |
|
|
|
|
|
All LED’s “FLASHING” | The Dispenser has detected an |
Fauly Detected | Internal Fault |
Remove the Lower Splash Guard to view the Fault Message, see Diagnostics. After the fault has been repaired or corrected, hold the “STOP” button for 10 seconds to clear the message.