10

SLCA-7 PROGRAMMING

LED DISPLAY PROGRAM MODE DESCRIPTION
Program Mode: Used to change or enter new set-up values.
To enter the Program Mode, Set the RUN/NIGHT/PROGRAM Switch to the PROGRAM position, the unit will
display “__PPP” to indicate it is in the Program Mode. Use the MENU switch to scroll to the next display. Use
the Increase (+) and Decrease (-) switch to adjust the values.
MENU (-) (+)
10 1 9 020 1 8 0
MENU (-) (+)
30 1 5 540 r u n40 7 650 r u n50 8 3
Tank Temperature
Set Tank Ready Temperature
Refill Threshold
Left hopper motor
Left hopper motor
Right hopper motor
Right hopper motor
Default = 190°F
Default = 180°F
Set tank refill threshold
Default = 155
Press any beverage dispense switch,
left hopper motor will run for 10 sec-
onds.
Set left hopper auger power level
Default = 76
Press any beverage dispense switch,
right hopper motor will run for 10
seconds.
Set right hopper auger power level
Default = 83
39328.3 012113