6
OPERATING CONTROLS AND INTERFACE
1. Cup Size Buttons: Momentarily pushed to select beverage size to dispense.
2. Stop Button: Momentary pushed to stop dispensing.
3. Decaf Button: Momentarily pushed to select Decaffeinated coffee.
4. Dispense Buttons: Momentarily pushed to dispense selected beverage.
5. Decaf refill LED: Illuminates when left (Decaf) concentrate can needs replaced.
6. Coffee (Hot Chocolate) refill LED: Illuminates when right (Regular) concentrate can needs replaced.
7. Main Power Switch: Removes AC power to tank heater and control circuits.
8. Function Selector Switch: Allows the user to select different dispensing functions (Located behind the
splash guard panel)
a. Rinse: Dispenses hot water only- Flushes the powder and coffee mixing chambers and dispense lines
and tips.
b. Prime: Dispenses concentrates only – Primes concentrate pumps.
c. Normal: Normal dispense mode – Dispenses mixed product.
9. Mode Selector Switch: Allows the user to select different operating modes.
a. Run: Normal operating position.
b. Night: Anti-pilfering mode that disables dispensing, but keeps heater and chiller operational.
WARNING – The NIGHT Mode does not remove AC power from the dispenser. Disconnect power source before
servicing the dispenser.
c. Program: Enables programming and set up of the dispenser.
10. Programming Switches: Used in conjunction with the LED display to program and calibrate the dispenser to
customer specific requirements.
a. Menu: used to scroll to the next menu screen.
b. (+): used to increase the display value.
c. (-): used to decrease the display value.
11. LED Display: Displays programming menus and fault messages.