C3 & C4 RATINGS
BOILER | BURNER | DOE HEATING | I=B=R NET | MINIMUMCHIMNEY REQUIREMENTS |
| ||
MODEL | CAPACITY | CAPACITY MBH | RATINGS | ROUND IN | RECTANGLE | HEIGHT |
|
(1) | GPH (2) | (3) | MBH (4) | DIAMETER | IN. x IN. | (FT.) | AFUE % |
C3 | 0.75 | 89 | 77 | 6 | 8 x 8 | 15 | 83.5 |
|
|
|
|
|
|
|
|
C4 | 1.20 | 140 | 121 | 6 | 8 x 8 | 15 | 81.7 |
|
|
|
|
|
|
|
|
Notes:
1.Available as a packaged water boiler only.
2.The Burner Capacity is based on oil having a heating value of 140,000 BTU/GAL.
3.DOE Heating Capacity and Annual Fuel Utilization Efficiency (AFUE) are based on U.S. Government tests at 13.0% CO2 with No. 1 maximum smoke and
4.Net I=B selecting boiler.
Maximum Working Pressure: 30 PSI water.
C3 & C4 DIMENSIONS AND STANDARD EQUIPMENT
Boiler Model | A | B | C |
C3 | 16" | 6" | |
C4 | 20" | 6" | |
|
|
| Standard Equipment: |
|
|
| • Cast Iron Section Assembly |
|
|
| • Deluxe Insulated Jacket |
|
|
| • Burner Swing Door & |
|
|
| Mounting Plate Beckett |
|
|
| • Flame Retention Burner |
|
|
| • Boiler Drain Valve |
|
|
| • Barometric Draft Regulator |
|
|
| 14000 Volt Electric Ignitor |
|
|
| • Solenoid Oil Valve |
|
|
| • |
|
|
| • Relief Valve |
|
|
| • Combination High Limit |
|
|
| Circulator Relay Control |
|
|
| • Pressure/Temperature Gauge |
|
|
| • Protectorelay Control |
|
|
| Circulator |
OPTIONAL TANKLESS HEATERS
OPTIONAL TANKLESS HEATERS
BOILER | HEATER | HEATER GPM |
MODEL | MODEL | OUTPUT (1) |
|
|
|
C3 | 3.25 | |
|
|
|
C4 | 3.5 | |
|
|
|
Notes:
1.Tankless heater rating G.P.M. based on 100°F rise with 40°F inlet water (intermittent draw) with boiler water temperature of 200° F.
Other Optional Equipment:
•Two stage fuel unit
LIFETIME LIMITED WARRANTY
Every C3 & C4 cast iron heat exchanger is covered by Burnham's Lifetime True Blue Limited Warranty.
Form No.
Printed in the U.S.A.
©2005 U.S. Boiler Company, Inc. - Lancaster,PA