Table 2: Vent System Components Included with Boiler

Vent System Components

Part Number

 

 

Gasketed Vent Terminal 3"

8110701

Horizontal (SCG-3 thru SCG-7)

 

 

 

Gasketed Vent Terminal 4"

8110702

Horizontal (SCG-8 & SCG 9)

 

 

 

Disc Air Intake - 3"

6116045

(SCG-3 & SCG-4)

 

 

 

Disc Air Intake - 4"

6116049

(SCG-5 & SCG-6)

 

 

 

Air Intake - 5"

6116063

(SCG-7 thru SCG-9)

 

 

 

Table 3: Burnham Vent System and Air Intake System Components

 

Vent System

Part

Equivalent

 

Component

Number

Feet of Pipe

 

 

 

 

3

" Dia. Pipe x 1 Ft

8116296U

1

 

 

 

4

" Dia. Pipe x 1 Ft

100176-01

 

 

 

 

 

3

" Dia. Pipe x 3 Ft

8116298U

3

 

 

 

4

" Dia. Pipe x 3 Ft

100177-01

 

 

 

 

 

3

" Dia. Pipe x 5 Ft

8116300U

5

 

 

 

4

" Dia. Pipe x 5 Ft

100178-01

 

 

 

 

 

3

" Dia. Pipe x Adjustable

8116319U

**Equal to

 

 

 

Installed Length

4

" Dia. Pipe x Adjustable

100179-01

(1.06 to 1.64)

 

 

 

 

3

" Dia. 90° Elbow

8116294U

5

 

 

 

4

" Dia. 90° Elbow

100180-01

 

 

 

 

 

3

" Dia. 45° Elbow

8116292U

5

 

 

 

4

" Dia. 45° Elbow

100181-01

 

 

 

 

 

3

" Dia. Horizontal Drain Tee

8166302U

 

 

 

4

" Dia. Horizontal Drain Tee

100182-01

 

 

 

 

 

3

" Dia. Vertical Drain Tee

8116304U

 

 

 

4

" Dia. Vertical Drain Tee

100183-01

 

 

 

 

 

3

" Single Wall Thimble

8116116

---

 

 

 

4

" Single Wall Thimble

100184-01

 

 

 

 

 

3

" Double Wall Thimble

8116115

---

 

 

 

4

" Double Wall Thimble

100185-01

 

 

 

 

 

Intake System

Equivalent

Components

Feet of Pipe *

(Parts by Others)

 

 

 

3", 4", or 5" ID Pipe x 1 Ft

1

 

 

3", 4", or 5" ID Pipe x 2 Ft

2

 

 

3", 4", or 5" ID Pipe x 4 Ft

4

 

 

3", 4", or 5" ID Pipe x 5 Ft

5

 

 

3", or 4" 90° Elbow

5

 

 

3", or 4" 45° Elbow

5

 

 

5" 90° Elbow

6

 

 

5" 45° Elbow

6

 

 

*Equivalent Feet of Pipe Based on Standard 4" Smoke Pipe Design

Table 4: Vent/Air Intake Length

 

 

3" Air Intake Pipe

4" Air IntakePipe

5" Air IntakePipe

3" Vent Pipe

4" Vent Pipe

Model

(Equiv. Ft.)

(Equiv. Ft.)

(Equiv. Ft.)

(Equiv. Ft.)

(Equiv. Ft.)

 

 

 

 

 

 

 

 

 

 

 

 

Min.

Max.

Min.

Max.

Min.

Max.

Min.

Max.

Min.

Max.

 

 

 

 

 

 

 

 

 

 

 

 

SCG-3

& SCG-4

8

50

----

----

----

----

8

50

----

----

 

 

 

 

 

 

 

 

 

 

 

 

SCG-5

& SCG-6

----

----

8

50

----

----

8

50

----

----

 

 

 

 

 

 

 

 

 

 

 

SCG-7

----

----

----

----

8

50

8

50

----

----

 

 

 

 

 

 

 

 

 

 

 

 

SCG-8

& SCG-9

----

----

----

----

8

40

----

----

8

40

9