Ethernet Full Duplex Configuration Screen

Local Management Supplement 1-17

Figure 1-8 Ethernet Full Duplex Configuration Screen
This section explains each field of the Ethernet Full Duplex Configuration screen.

PORT # (Read-only)

Identifies the number of the port.

OPERATION MODE (Toggle)

Allows the user to set the specified port to transmit and receive data separately (Standard) or simultaneously (Full Duplex). Set this field to one of the following values:STANDARD ENET – The port is running in half duplex (default) and either transmits data or receives data, but not both at the same time. To set Ethernet ports for Standard operation, refer to Section 1.7.1.FULL DUPLEX – Depending on the SmartSwitch, the port transmits and receives data simultaneously at 10 or 100 Mbps, thus enabling the port to effectively switch at 20 or 200 Mbps. To set Ethernet ports for Full Duplex operation, refer to Section 1.7.1.
19601-21
PORT #
1
2
3
4
5
6
7
8
9
10
11
12
LINK STATUS
Link
Link
Link
No Link
Link
Link
Link
Link
Link
Link
Link
Link
SAVE
OPERATION MODE
[STANDARD ENET]
[STANDARD ENET]
[STANDARD ENET]
[STANDARD ENET]
[STANDARD ENET]
[STANDARD ENET]
[STANDARD ENET]
[STANDARD ENET]
[STANDARD ENET]
[STANDARD ENET]
[STANDARD ENET]
[STANDARD ENET]
PORT STATUS
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
SET ALL PORTS: FULL
RETURN
RETURN
[13-24]
EXIT