Chapter 3: LM Security Screens for 2H23-50R/2H33-37R Devices
3-6 Local Management Supplement
3. Press ENTER to display the repeater port settings on that connector.
4. Use the arrow keys to highlight the PORT STAT. field of the repeater
port being enabled or disabled.
5. Use the SPACE bar to toggle to the appropriate setting (Enable or
Disable).
6. If setting more than one repeater port, repeat steps 4 and 5 for each one
and then proceed to step 7.
7. Use the arrow keys to highlight the SAVE command.
8. Press ENTER. The message “SAVED OK” displays and all settings
are saved.
3.2.3 Setting Operating Mode On All Repeater Ports
The repeater ports on a connector can be set to the same operating mode
simultaneously using the SET ALL PORTS field, as follows:
1. Use the arrow keys to highlight the CONNECTOR # field.
2. Use the SPACE bar to step to the appropriate connector number.
3. Press ENTER to display the repeater port settings on that connector.
4. Use the arrow keys to highlight the SET ALL PORTS field.
5. Use the SPACE bar to step to the appropriate Operating Mode
(Auto-Neg, 10Base-T, or 100Base-TX).
6. Press ENTER.
7. Enable or disable each repeater port as needed. Refer to Section 3.2.2
for instructions.
8. Use the arrow keys to highlight the SAVE command.
9. Press ENTER. The message “SAVED OK” displays and all repeater
ports of the connector are set to the selected operating mode.
NOTE If LockedOnAddr is chosen as the Security State, the individual
port must be configured in the Port Level Security
Configuration screen. Sections 3.4 provides instructions for
configuring individual ports.