Cabletron Systems ESX-1380 manual Power Supply Operation, LANVIEW Diagnostic LEDs

Models: ESX-1380

1 2
Download 2 pages 37.3 Kb
Page 2
Image 2
Power Supply Operation

Power Supply Operation

Power Supply Operation

The ESX-1320R and the ESX-1380R are equipped with two load sharing power supplies to provide redundancy. Two power cord outlets, labeled Power 1 and Power 2 (see Figure 1), are used to provide power to each power supply. To take advantage of the load sharing and redundancy capabilities, each power cord must be plugged into a dedicated ac outlet.

LANVIEW Diagnostic LEDs

In addition to the LANVIEW LEDs located on the front panel of the ESX-1320 and the ESX-1380, the ESX-1320R and the ESX-1380R are equipped with two LANVIEW diagnostic LEDs located on the rear of the unit (see Figure 1). These LEDs provide an easy way to observe the status of the individual power supplies. Table 1 provides a description of the LANVIEW power supply LEDs.

Table 1 LANVIEW Power Supply LEDs

LED

Color

Description

 

 

 

 

 

 

PWR 1

Green

Power Supply 1 is operating correctly.

 

 

Red

Power Supply 1 is not operational.

 

 

 

 

PWR 2

Green

Power Supply 2 is operating correctly.

 

 

Red

Power Supply 2 is not operational.

 

 

 

 

Physical Properties (ESX-1320R or ESX-1380R)

Dimensions:

6.86H x 43.18W x 46.99D (cm)

 

2.7H x 17W x 18.5D (in)

Weight (Unit):

5.45 kg (12 lb)

Electrical Specifications (ESX-1320R or ESX-1380R)

Input:

100-125 V ~ /4.0 A

 

200-250 V ~ / 2.0 A

Phasing:

Single-phase

Frequency:

50/60 Hz