FILLING OPERATIONS
CADET 86038220

3-5

FILLING THE CADET
NOTE: Use clean bucket of water to fill solution tank
Do not put defoamer, solvents, spotter or
prespray chemicals in the solution tank.
Do not allow water to spill into vacuum motor inlet.
Dry spillage from top of solution tank before
replacing recovery tank.
CHEMICALS
Suitable Chemicals Non-Compatible Chemicals
Alkalis Aldehydes
Detergents Aromatic Hydrocarbons
Hydroxides SP Buty ls
Soaps Carbon Tetrachloride
Vinegar Clorox*
Chlorinated Bleaches
Chlorinated Hydrocarbons
Lysol*
Methyl Ethel Ketone (MEK)
Perchorethylene (perc)
Phenolics
Trichlorethylene
D-Limonene
Remove recovery
tank
Add water
Add cleaning
chemical
Replace recovery
tank
7 gal.
(26.5 ltr.)
7 – 14oz.
(207ml – 414ml)
RECOVERY TANK
SOLUTION
TANK
140°F
(
60°C
)
STEP
1
STEP
2
STEP
3
STEP
4
FILL LINE