| Spa Model | GFCI Required | Wires Required | |
| All 230V spas (except | One 32 amp RCD | Four #10 AWG | |
| 6205 control boxes | or two 16 amp | copper wires | |
Spas | requiring high amperage | RCDs |
| |
- see below) |
|
| ||
Spas with the 6300 | One 32 amp RCD | Four #10 AWG | ||
Portable | ||||
control box (when high | or two 16 amp | copper wires | ||
amperage is selected on | RCDs |
| ||
circuit board) |
|
| ||
SEE CONFIGURATION |
|
| ||
|
|
| ||
| INSTRUCTIONS ON |
|
| |
| NEXT PAGE. |
|
| |
|
|
|
| |
Spas | Ultimate Fitness spas | One 32 amp RCD | Four #10 AWG | |
with one 5.5 kW heater | or two 16 amp | copper wires | ||
| RCDs |
| ||
Fitness |
|
| ||
| Service 1: One 32 | Service 1: Four #10 | ||
| amp RCD or two 16 | AWG copper wires | ||
Ultimate Fitness spas | amp RCDs |
| ||
Ultimate |
| |||
with two 5.5 kW heaters | Service 2: One 32 | Service 2: Three #10 | ||
| amp RCD or two 16 | AWG copper wires | ||
| amp RCDs |
| ||
|
|
| ||
|
|
|
| |
| Designer | One 32 amp RCD | Four #10 AWG | |
Spas | with one 3 kW heater | or two 16 amp | copper wires | |
| RCDs |
| ||
| Service 1: One 32 | Service 1: Four #10 | ||
| ||||
Designer | amp RCD or two 16 | AWG copper wires | ||
amp RCDs |
| |||
with one 3 kW heater |
| |||
Service 2: One 32 | Service 2: Three #10 | |||
and one 5.5 kW heater | ||||
|
| amp RCD or two 16 | AWG copper wires | |
|
| amp RCDs |
|
Testing the RCD Breaker
Test the RCD breaker prior to first use and periodically when the spa is powered. To test the RCD breaker follow these instructions (spa should be operating):
1.Press the TEST button on the RCD. The RCD will trip and the spa will shut off.
2.Reset the RCD breaker by switching the breaker to the full OFF position, wait a moment, then turn the breaker back on. The spa should have power again.
14