FibreQuik - Fibre Channel Adapter User Guide
Topology: NL
AL_PA: 0xef
Adapter_ID: 0
or for fabric:
Topology: F
Port_name: 0x00011000
Adapter_ID: 255
Make sure that the id value doesn't conflict with any other host
or device on the same fibre channel loop. The other attributes
will be different on each card.
During boot, the number displayed when configuring the
adapter is hex 0x911 (FC adapter).
/usr/lpp/cbxfc/mbtest scsi1
This test code may be used to get fibre channel status from the
adapter or from attached devices.
/usr/lpp/cbxfc/sctest scsi1
This test code may be used to get IOCINFO information from
the adapter or to see the results of SCSI Inquiry or
TestUnitReady commands to SCSI devices attached to the
adapter.
/usr/lpp/cbxfc/fctest
This script will print a cross reference between AIX SCSI ID
and LUN number and the Fibre Channel WWN and FC LUN as
well as PORTID and an internal ID (l_id) used by the driver.
/usr/lpp/cbxfc/runtrace
This should be run to start a trace if Cambex support requests a
trace of the card failure. The AIX trace facility,
bos.sysmgt.trace, must be installed. To stop the trace and
generate a trace report, type:
trcstop; trcrpt > /tmp/trc.log
- 11 -