Operating Instructions | SB504000 |
Operating Instructions (Continued)
ADJUSTING THE DIRECTION OF THE EXHAUST
The tool is equipped |
| |
with an adjustable |
| |
direction exhaust |
| |
deflector. This is |
| |
intended to allow | Rotate | |
the user to change | ||
|
the direction of the exhaust. Simply twist the deflector to any direction desired.
User - Maintenance
Instructions
CLEARING A JAM FROM THE TOOL
1. Disconnect the air supply from the tool.
2. Remove all nails from the magazine (see Loading/ Unloading). Failure to do so will
cause the nails to
eject from the front of the tool.
3.Loosen cap screws on nose of tool. Slide nose downward and remove from tool to expose jammed fastener.
4.Reinstall nose assembly in reverse order in Step #3.
5.Make sure the trigger and Work Contact Element (WCE) move freely up and down without sticking or binding.
TECHNICAL SERVICE
Please call our Tool Hotline at
FASTENER AND REPLACEMENT PARTS
Use only genuine Campbell Hausfeld
18 gauge fasteners (or equivalent - see Fastener Interchange Information). Tool performance, safety and durability could be reduced if improper fasteners are used. When ordering replacement parts or fasteners, specify by part number.
TOOL REPAIR
Only qualified personnel should repair the tool and they should use genuine Campbell Hausfeld replacement parts and accessories, or parts and accessories which perform equivalently.
ASSEMBLY PROCEDURE FOR SEALS
When repairing a tool, the internal parts must be cleaned and lubricated. Parker
STORAGE
The tool should be stored in a cool dry place.