Operating Instructions and Parts Manual | CHN70800 | |
| ||
Lubrication | 70 psi Minimum | |
This nailer requires no lubrication for normal operation. However, lubrication will | ||
| ||
not harm the tool. | 120 psi Maximum | |
| ||
The work surface can become damaged by excessive lubrication. | Chart 1 | |
|
Minimum Components Required For
AIR COMPRESSOR: The air compressor must be able to maintain a minimum of 70 psi when the nailer is being used. An inadequate air supply can cause a loss of power and inconsistent driving (see Chart 1).
PRESSURE REGULATOR: A pressure regulator is required to control the operating pressure of the nailer between 70 psi and 120 psi.
AIR SUPPLY HOSE: Always use air supply hoses with a minimum working pressure rating equal to or greater than the pressure from the power source, or 150 psi, whichever is greater. Use 1/4 inch air hose for runs up to 50 feet. Use 3/8 inch air hoses for 50 ft. run or longer (see Figure 7 and Chart 2).
Figure 8 shows the recommended hookup for the nailer.
NOTE: For better performance, install a 3/8 inch quick plug (1/4 inch NPT threads) with an inside diameter of 0.315 inch (8 mm) on the nailer and a 3/8 inch quick coupler on the air hose.
1.With ON/OFF switch in OFF position, plug compressor into electrical outlet.
2.Close pressure regulator by turning all the way to the left. Turn compressor ON and let it pump all the way up to automatic
3.Attach air hose to regulator outlet. Adjust pressure regulator by turning to the right so that outlet pressure is between 70 psi to 120 psi.
4.Load fasteners into nailer (See Loading/Unloading the Nailer section on page 11).
5.Point the nailer in a safe direction while attaching to air hose.
6.Nailer is ready for use. You may need to adjust outlet pressure to achieve proper fastener depth.
Rated 150 psi or greater
Interior Diameter
Figure 7 - Air Hose Requirements
Air Hose Requirements
Diameter | Length of Run |
|
|
3/8 inch | Less than 50 feet |
|
|
1/2 inch | Greater than or equal |
| to 50 feet |
|
|
Chart 2 |
|
| Outlet |
|
|
|
Tank | Pressure |
|
|
|
Gauge |
|
|
| |
Pressure |
|
|
| |
|
|
|
| |
Gauge | Regulator | Quick |
|
|
| Outlet | Coupler | Quick | Swivel |
|
|
| Coupler | Plug |
Regulator
Quick
Plug
Air
Hose
Figure 8 - Recommended Hookup
10www.chpower.com