Operating Instructions and Parts Manual

CHN70200

 

 

Pre-Operation (Continued)

5.Depress the WCE against the work surface without pulling the trigger (See Figure 16). The nailer must not operate. Do not use the tool if it operates without pulling the trigger. Personal injury may result.

6.Remove nailer from work surface. The WCE must return to its original down position. Pull the trigger (See Figure 17). The nailer must not operate. Do not use the tool if it operates while lifted from the work surface. Personal injury may result.

7.Pull the trigger and depress the WCE against the work surface. The nailer MUST operate when in bump mode. The nailer MUST NOT operate if in sequential mode.

8.Depress the WCE against work surface. Pull the trigger. The nailer MUST operate.

9.Switch nailer into the other Mode as described in Operational Modes section and repeat.

IMPORTANT: Repeat steps one through nine with tool in Safety Lockout Mode. Tool should not operate at any step. If tool does operate while in Safety Lockout Mode, contact Campbell Hausfeld for technical support.

Electronics ON / OFF Switch

Located on the battery compartment is an ON/ OFF for the tool’s electronic functions, low nail indicator LEDs, and nail placement laser.

To utilize the function, turn the battery switch to the “ON” position. To avoid unwanted battery depletion during storage, turn the switch to the “OFF” position.

Work Surface

Figure 16

Work Surface

Figure 17

Figure 18 - Electronic ON/OFF Switch

www.chpower.com 13