Operating Instructions and Assembly Instructions

Airless Paint Sprayers

Storage

short term

(less than one week)

WEAR ALL NECESSARY

SAFETY GEAR

Necessary Tools / Materials:

Pump Protector Solution

Plastic Wrap

3/4 in. or Adjustable Wrench

Oil or Alkyd Based Paint

If sprayer cleaned with mineral spirits, simply wrap suction filter housing

in plastic to keep debris out of suction filter. No other preparation is necessary.

Water-based paint

1.

Prepare Pump Protector solution in

 

bucket as directed on container.

2.

Place suction assembly into

 

solution.

3.

Place end of bypass tube into waste

 

bucket.

4.

With prime/spray control in PRIME

 

position, turn pressure to HIGH

 

(completely clockwise).

5.

Turn power switch ON. Circulate

 

Pump Protector through bypass

 

tube until bucket of solution is

 

EMPTY.

6.

Turn pressure to LOW (completely

 

counterclockwise).

7.

Wrap suction filter housing in

Water Based Paint

1

2

PUMP

PROTECTION

 

SOLUTION

 

Pump

 

 

Protector

WASTE

 

BUCKET

Place Suction Assembly in

Prepare PumpSolution

Protector Solution

3

4

PUMP

PROTECTION

PUMP

SOLUTION

PROTECTION

 

SOLUTION

 

 

WASTE

WASTE

BUCKET

 

BUCKET

 

 

With Prime/Spray

Place End of Bypass Tube

Control in PRIME

into Waste Bucket

Position, Turn

 

 

Pressure to HIGH

 

(completely clockwise)

plastic to keep debris out of suction

filter.

long term

(more than one weeK)

8.

Remove high pressure hose and

 

drain. Reassemble high pressure

 

hose to pump.

9.

With spray tip attached to spray

6

7

Wrap Suction Filter

Housing in Plastic

gun, wrap tip with plastic to

protect tip.

Turn Pressure to LOW

(completely counterclockwise)

www.chpower.com

14