Operating Instructions and Assembly Instructions

Airless Paint Sprayers

Cleanup for Changing Paints or Temporary Storage for More Than One Night (Continued)

Cleaning Hose and Gun

Allow the cleaning fluid to continue circulating for approximately 10 minutes.

7.

Turn pressure to HIGH (completely

 

clockwise).

8.

Turn prime/spray control to SPRAY

 

position.

7

8

9

Turn Prime/ Spray

9. Rotate spray tip to CLEAN position.

10. Point spray gun into bucket of

paint and pull trigger.

NOTE: To reduce splashing, direct

fluid stream along inside of bucket

and above the paint level.

11. As soon as cleaning fluid is flowing

from spray gun, release trigger.

NOTE: It should take less than one

minute to clear each 25 feet of high

pressure hose.

12. Engage gun trigger lock.

13. Turn prime/spray control to PRIME

position.

14. Turn pressure control to HIGH.

15. Lift suction assembly above fluid

level in bucket.

NOTE: Allow pump to run until

empty.

16. Repeat process (1 - 15) with

fresh cleaning fluid, to remove

contaminated cleaning fluid from

initial cleaning.

Control to SPRAY (knob is horizontal) If Reversible Tip is

Used, Rotate Spray Tip

Turn Pressure to HIGHto CLEAN Position. (completely clockwise).

12

10

To Lock

Locked

Engage Gun Trigger Lock

13

 

Paint

 

While Pulling Trigger,

 

Direct Fluid Stream Along

Prime Position

Inside of Bucket

1415

High Pressure Position

(completely clockwise)

Lift Suction

Assembly

www.chpower.com