Operating Instructions and Assembly Instructions
Airless Paint Sprayers
Cleanup for Changing Paints or Temporary Storage for More Than One Night
WEAR ALL NECESSARY
SAFETY GEAR Necessary Tools / Materials:
•Rag
•Gloves
•Two (2) buckets
•At least one (1) gallon of clean- ing fluid (water or mineral spirits depending on coating type)
•Cleaning brush
NOTE: Do NOT disconnect any hoses.
1.Turn prime/spray control to PRIME position.
2.Turn power switch to ON.
High pressure
hose may still be pressurized with prime/spray control in the PRIME position. With the gun pointed in a safe direction, pull the gun trigger to relieve any pressure in the hose.
3.Turn pressure to HIGH (completely clockwise).
4.Lift suction assembly above fluid level in bucket.
While holding suction assembly above paint level, allow pump to run until empty.
5.Immediately place both suction assembly and bypass tube in a bucket containing enough cleaning fluid to cover suction filter by two inches. Allow pump to prime and begin circulating fluid.
6.While fluid is circulating, soak rag in fluid and wipe exterior of suction assembly and bypass tube. Remove suction filter. Wipe suction filter with rag removing excess paint buildup. Reinsert filter into suction tube.
Cleaning Pump
1
Turn Prime/Spray
Control to PRIME
Position
3
Turn Pressure to HIGH (completely clockwise)
5
Suction Assembly and
Bypass Tube in Bucket
of cleaning fluid
2
Turn power switch to ON (shown in the OFF position)
4
Lift Suction Assembly above
Paint Level in Bucket
6
Wipe Exterior of Suction
Assembly and Bypass Tube
www.chpower.com
11