Operating Instructions and Assembly Instructions
Troubleshooting Chart (Continued)
Symptom | Possible Cause(s) | Corrective Action |
|
|
|
Pump primes and builds pressure, but does not maintain pressure once trigger is pulled
21.Clogged Suction Filter | 21.Remove Suction Filter and clean. Also, refer to Maintenance |
| section |
22.Suction Assembly loose and/or | 22.Remove Suction Assembly, clean sealing surfaces and |
sealing surfaces are dirty at Inlet | reassemble |
Valve |
|
23.Paint thick due to cold weather. This problem usually occurs with Latex based coatings
24.Inlet Valve and/or Outlet Valve are worn
23.Do not paint Latex coatings in temperatures less than 50°F (10°C). Refer to paint manufactures minimum painting temperature recommendations
24.Replace valves. Also, refer to Maintenance section
Gun will not | 25.Trash caught in Gun Valve | 25.Clean or replace Gun valve. Also, refer to Gun Maintenance |
|
| section. This is a very rare occurrence, and will not occur if filters |
|
| are properly maintained |
| 26.Worn Gun Valve | 26.Replace Gun valve. Also, refer to Gun Maintenance section |
| 27.Dried paint under gun actuator | 27.Remove 1/4” nut and gun actuator at rear of gun. Remove |
|
| dried paint from around needle and back of actuator. Replace |
|
| actuator and 1/4” nut. Set gun trigger position with trigger |
|
| lock in locked orientation (tabs horizontal) by the following |
|
| instructions: With one hand holding trigger softly against |
|
| lock, use a 1/4” nut driver to turn nut in until trigger starts to |
|
| come off the lock, then back off the nut (counterclockwise) 1/2 |
|
| turn. Pulling the trigger must not open the gun valve when |
|
| trigger lock is activated. You should be able to get the actuator |
|
| to wiggle slightly with your finger while holding the trigger |
|
| against the locked trigger lock. |
|
|
|
After moving equipment or | 28.Suction assembly loose or | 28.Tighten suction assembly onto inlet valve. |
adding paint to bucket, unit | damaged | problem is not remedied, consult Technical Support |
will not prime or spray |
|
|
Oil in Paint | 29.Pump was not flushed prior to |
| use |
29.Flush unit prior to use (See preparation section).
Fluid leaks | 30.Loose connection | 30.Clean sealing surface and reassemble per assembly instructions |
| 31.Contaminated sealing surface | 31.Consult technical support |
| 32.Damaged component | 32.Consult technical support |
|
|
|
Symptoms not listed or | 33.Possible product quality issue. | 33.Call technical support at |
unsuccessful in resolving issue | (We would greatly appreciate |
|
| your assistance in continuous |
|
| product quality improvement) |
|
|
|
|
www.chpower.com