21: End (P95) | End Then Do/Else/End |
END COOLER CONTROL LOGIC
START FAN CONTROL LOGIC BASED ON HEATER/COOLER
22: If X<=>F (P89) | If heater is on | ||
1: | X Loc |
| |
2: | 2 | <> |
|
3: | 0 | F | Set flag 1 |
4: | 11 | Set high Flag 1 | |
23: If X<=>F (P89) | If cooler is on | ||
1: | X Loc |
| |
2: | 2 | <> |
|
3: | 0 | F | Set flag 1 |
4: | 11 | Set high Flag 1 | |
24: | If Flag/Port (P91) | If flag 1 is set | |
1: | 11 | Do if flag 1 is high | Then |
2: | 30 | Then Do | |
25: Z=F (P30) |
| Put a "1" into fan | |
1: | 1 | F | control location |
2: | 0 | Exponent of 10 |
|
3: | Z Loc: |
| |
26: Else (P94) |
| Else, If flag 1 is reset | |
27: Z=F (P30) |
| Put a "0" into fan | |
1: | 0 | F | control location |
2: | 0 | Exponent of 10 |
|
3: | Z Loc : |
| |
28: End (P95) |
| End Then Do/Else/End | |
29: Do (P86) |
| Reset flag 1 | |
1: | 21 | Set low Flag 1 |
|
30: End Loop (P95) | End Master Loop |
END FAN CONTROL LOGIC BASED ON HEATER/COOLER START FAN CONTROL LOGIC BASED ON TIME
31: | If time is (P92) |
| If 5 minutes remain |
1: | 10 | minutes into a | out of 15 minute |
2: | 15 | minute interval | interval, |
3: | 12 | Set high Flag 2 | set flag 2 |
14