TECHNICAL DATA

Gas connection

Rp ½ (½" BSP female)

 

 

 

Pressure test point

Front left hotplate injector

 

 

 

Gas rate adjustment

None

 

 

 

Aeration adjustment

None

 

 

 

Electrical connection

Flexible cord fitted with a 3 pin 13 amp plug

 

 

 

230/240V a.c. 50Hz. 13A fuse.

 

 

 

 

 

 

 

 

 

 

 

 

G20 at 20mbar

G30 at 28-30mbar

 

 

G31 at 37mbar

 

 

 

 

 

 

 

 

 

 

 

 

BURNER

 

HEAT INPUT

 

INJECTOR

HEAT INPUT

INJECTOR

 

 

 

 

 

 

 

HOTPLATE

 

3.0 kW

 

116

3.0 kW (220g/h)

86

Front Left and Rear Right

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HOTPLATE

 

2.0 kW

 

103

2.0 kW (145g/h)

70

Front Right and Rear Left

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Grill

 

3.7 kW

 

150

3.4 kW (200g/h)

91

 

 

 

 

 

 

 

Main Oven

 

2.5 kW

 

115

2.3 kW (165g/h)

71

 

 

 

 

 

 

 

Top Oven

 

1.9 kW

 

100

1.9 kW (135g/h)

66

 

 

 

 

 

 

 

29