PERSONAL INJURY HAZARD
Failure to follow this caution may result in personal injury.
Ozone in concentrations above 0.05 PPM may be
hazardous to health.
Des concentrations d’ozone superieures a 0.05 PPM
peuvent etre nocives pour la sante.
CAUTION
!
APPLICATION CONSIDERATIONS
The InfinitytAir Purifier is designed for use in the return air
duct of a forced air heating, cooling, and ventilation system.
Models GAPABXCC1620, GAPABXCC2020 and
GAPABXCC2420 are specifically designed for use in systems
with a fan coil.
Air Conditioning
The InfinitytAir Purifier should be installed in a system so that
all the return air is circulated through the air purifier. It should be
located upstream of the fan coil This will help keep the fan coil
clean and prevent condensation from forming within the
InfinitytAir Purifier.
Humidifiers
An evaporative humidifier can be mounted upstream of the
InfinitytAir Purifier. It is best to install atomizing humidifiers
downstream of the air purifier because hard water salt deposits
and water droplets may damage the air purifier. If an atomizing
humidifier must be mounted upstream of the InfinitytAir
Purifier, it should be mounted as far upstream as possible (at least
6 ft. recommended), and a standard disposable furnace filter
should be mounted between the humidifier and the air purifier to
trap hard water salt deposits and water droplets.
Transitions
If the return air duct or fan coil openings do not fit the Infinityt
Air Purifier cabinet openings, gradual transitions are
recommended to reduce air turbulence and maximize efficiency.
No more than 20 degrees (about 4 in. per running ft.) of
expansion should be used on each side of the transition fitting.
Turning Vanes
If the InfinitytAir Purifier is installed adjacent to a 90 degree
duct elbow, turning vanes should be added inside duct to improve
air distribution across the face of the air purifier.
Electrical Power / Air Flow Sensor
The InfinitytAir Purifier should only be powered when airflow
is present. This model is designed for use with a fan coil and is
equipped with an air flow sensor which provides power only
when the fan coil blower is operating (See Fig. 2). InfinitytAir
Purifier models GAPABXCC1620, GAPABXCC2020, and
GAPABXCC2420 are designed to be powered from a 208/230
VAC power source.
A06387
Fig. 2 --- Air Flow Sensor
Door (x1) Cabinet (x1) Enhancement Module (x1) Safety Screen (x1)
Return Duct Adapters:
Long (x2) / Short (x2)
Air Flow Sensor (x1)
(x1)
(x2)
(x3)
(x1)
(x2)
Installation Components
(in bag attached to power cord)
Installation Manual
1
GAPA
Infinity Air Purifier
Sizes 1620, 2020, & 2420
Installation, Start---up, and
Operating Instructions
NOTE:Readthee
ntireinstruction
manualbeforestarting
the
install.
TABLEOFCONTENTS
Page
SAFETYCONSIDERA
TIONS1
........................
INTRODUCTION2
..................................
PLANNING2-
-5
.....................................
Application2
......................................
Ins
tallation
Requirements2..........................
Dimensions
Table13
...............................
AirConditioning5
.................................
Humidifiers5
.....................................
OutdoorAir5
.....................................
Sheet
MetalInstallation5
............................
Transitions5
......................................
Turning
Vanes5
...................................
Se
lectLocation5
...................................
Direction
ofAirflowthrough
AirPurifier5
..............
INSTALLATION5-
-6
.................................
Orientation5--6
....................................
Details 6.........................................
TypicalMounting
Positions6
.........................
Electrical
Installation6
..............................
Furnace
Application6
...............................
SYSTEMCHECKOUT7
..............................
MAINTENANCE7
..................................
Replacing
Purifier
Cartridge7
........................
TROUBLESHOOTING7
..............................
Recommended
Service
Tools7
........................
Indication
ofElectrical
Trouble7
......................
OTHERFACTSYOUS
HOULDKNOW7
...............
Ozone7
..........................................
HighAltitudeOperation7
...........................
Specifications
Table28
.............................
WARRANTY9
......................................
A05265
Fig.1-
-UnitGAPA
SAFETYCONSIDERATIONS
Improperinstallation,adjustment,
alteration,service,
maintenance,
orus
ecancaus
ee
xplos
ion,fire,e
lectrical
s
hock
orother
conditions
whichmaycause
personal
injuryorproperty
damage.Cons
ultaqualifiedins
taller
,s
e
rviceagency
,oryour
distributor
orbranch
forinformation
orassistance.
The
qualified
installer
oragency
mustusefactory
authorized
kitsor
accessories
whenmodifyingthisproduct.Refertot
he
individual
instructions
packaged
withthekitsoracces
s
ories
wheninstalling.
Followallsa
fetycodes.Wearsa
fetygla
sse
sandworkglove
s.
Usequenching
clothforbrazingoperations.Havefire
extinguisher
available.Readthese instructions
thoroughly
and
followallwarningorcautions
attached
totheunit.Consult
localbuilding
codesandNationalElectrical
Code(NEC)for
specialrequirements
.
Itisimportant
torecognize
safetyinformation.Thisisthe
safety--alertsymbol.Whenyouseethiss
ymbolontheunit
andininstructions
ormanuals,
bealerttothepotential
for
personal
injury
.Understand
thesignalwordsDANGER,
WARNING,andCAUTION.Thesewordsareu
sedwiththe
safety
-
-alerts
ymbol.DANGERidentifies
themostserious
hazards
whichwillresultins
evere
personal
injuryordeath.
WARNINGs
ignifieshazards
whichcoul dr
esultinpersonal
injuryordeath.CAUTIONisusedtoidentifyunsafe
practices
whichmayresultinpersonal
injuryorproduct
andproperty
damage.
NOTEisusedtohighlightsuggestions
whichwill
result
inenhanced
installation,
reliability
,o
roperation.
Air Purification Cartridge (x1)
(x2)
A07111
Fig. 3 --- InfinitytAir Purifier Components
GAPAB