FAN

2 STAGE

THERMIDISTAT

COIL

HEAT PUMP

 

 

Thermidistat

Variable Speed

Furnace

2-Stage

Heat Pump

25HPA6

RVS/Heat Stage 2

Heat Stage 1

Compressor Low

Compressor High

Fan

24VAC Hot Heating 24VAC Hot Cooling Dry Contact 1 Dry Contact 2 24VAC Common Humidify

Outdoor Air Temp

Remote Room Sensor

OAT/RRS Com

 

O

O

O/B W2

Y1

Y1

 

 

W/W1

W1

W1

 

REMOVE J2

 

 

Y1

W2

JUMPER FOR

HEAT STAGING

Y/Y2

Y/Y2

Y2

G

G

 

Rh

R

R

Rc

 

REMOVE J1 FOR

 

DEHUMIDIFY

 

DH

 

MODES

D1

 

 

 

D2

C

C

 

 

C

 

 

HUM

Humidifier Solenoid

 

OAT

Valve *

 

RRS

Outdoor Sensor *

 

OAT/RRS

Remote Room

 

 

 

 

Sensor *

 

RVS Cooling

O/B W2

W2

Heat Stage 3 (furnace)

W/W1

W/W1

Heat/Cool Stage 1

Y1 / W2

 

Heat/Cool Stage 2

Y/Y2

Y/Y2

Fan

G

G

24VAC Hot Heating

Rh

R

24VAC Hot Cooling

Rc

 

Dry Contact 1

D1

 

Dry Contact 2

D2

DHUM

24VAC Common

C

COM

Humidify

HUM

Humidifier Solenoid

Outdoor Air Temp

OAT

Valve *

Remote Room Sensor

RRS

Outdoor Sensor *

OAT/RRS Com

SRTN

Remote Room

 

 

Sensor *

* Indicates connection may not be required / available.

O

 

W2

*

Y1

 

Y/Y2

 

R

 

C

 

A08055

A09337

Fig. 10 - Edge Thermidistat Models TP-PRH-01 or TP-NRH-01)

Fig. 11 - Thermidistat Model TP-PRH-01 or TP-NRH-01 with

Wiring with 2-Stage Heat Pump (non-communicating)

Variable Speed Furnace and 2-Stage Heat Pump

 

(non-communicating)

User Interface

D

C

B

A

Humidifier

24vac C

Furnace or Fan Coil

Communicating HP

D D

C C

B B

A A

OAT

HUM C W O Y R

A08091

Fig. 12 - Infinity Furnace or Fan Coil Wiring with Communicating 2-Stage HP

LEGEND

24v Factory Wiring

24v Field Wiring

Field Splice Connection

A09306

14

Page 14
Image 14
Carrier 25HPA6 instruction manual Edge Thermidistat Models TP-PRH-01 or TP-NRH-01