38YCW 10 SEER
Visit www.carrier.com
Installation and Start-Up Instructions
NOTE: Read the entire instruction manual before starting the installation.
This symbol → indicates a change since the last issue.
SAFETY CONSIDERATIONS
Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause death, personal injury, or property damage. Consult a qualified installer, service agency, or your distributor or branch for information or assistance. The qualified installer or agency must use
Follow all safety codes. Wear safety glasses, protective clothing, and work gloves. Use quenching cloth for brazing operations. Have fire extinguisher available. Read these instructions thor- oughly and follow all warnings or cautions included in literature and attached to the unit. Consult local building codes and National Electrical Code (NEC) for special requirements.
Recognize safety information. This is the
Understand the signal words DANGER, WARNING, and CAU- TION. These words are used with the
Before installing, modifying, or servicing system, main elec- trical disconnect switch must be in the OFF position. There may be more than 1 disconnect switch. Lock out and tag switch(es) with a suitable warning label. Electrical shock can cause personal injury or death.
INTRODUCTION AND RECOMMENDATIONS
NOTE: In some cases noise has been traced to improper instal- lation of equipment.
1.Locate unit away from windows, patios, decks, and so forth where unit operation sounds may disturb customer.
2.Ensure that vapor- and
3.Run refrigerant tubes as directly as possible by avoiding unnecessary turns and bends.
A98525
Fig. 1—Model 38YCW
4.Leave some slack between structure and unit to absorb vibration.
5.When passing refrigerant tubes through the wall, seal opening with RTV or other pliable
6.Avoid direct refrigerant tubing contact with water pipes, duct work, floor joists, wall studs, floors, and walls.
7.Do not suspend refrigerant tubing from joists and studs with a rigid wire or strap that comes in direct contact with tubing. (See Fig. 2.)
8.Ensure that refrigerant tubing insulation is pliable and com- pletely surrounds vapor tube.
9.When necessary, use hanger straps which are 1 in. wide and conform to shape of tubing insulation. (See Fig. 2.)
10.Isolate hanger straps from insulation by using metal sleeves bent to conform to shape of insulation.
When outdoor unit is connected to
IMPORTANT: Maximum
IMPORTANT: Always install a
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book | 1 | 4 | PC 101 | Catalog No. | Printed in U.S.A. | Form | Pg 1 | Replaces: | |
Tab | 5a | 5a |
|
|
|
|
|
|
|