48TM007-012, 48TF004-014

 

 

Date:

Supersedes:

COMBINATION HEATING/COOLING

48T

Rev.:

 

 

UNITS

 

-1SB

 

 

 

 

 

JOB NAME:

LOCATION:

 

 

 

 

 

 

 

BUYER:

 

BUYER P.O. #

CARRIER #

 

 

 

 

 

UNIT NUMBER:

MODEL NUMBER:

 

 

 

 

 

 

UNIT DESIGNATION:

 

 

 

 

 

 

 

PERFORMANCE DATA CERTIFIED BY:

 

DATE:

 

 

 

 

 

 

 

 

DESCRIPTION

 

 

Units are a single piece, gas heating/electric cooling unit, with a low profile, pre-wired, tested and charged at the factory. The units have the capability for convertible supply and return openings and are intended for installation on an accessory curb (ordered separately), or for slab mounting (for horizontal duct connections). Units are designed to accept a field- installed economizer, enthalpy control, manual or 2-position outside air damper, roof curb, as well as 3 choices of gas heat. Refer to accessory chart below for full listing.

FEATURES

Standard one-year full product warranty.

Five-year protection plan for the motor-compressor.

Five-year protection plan on heat exchangers.

Outdoor ambient cooling operation from 25 F (–4 C) to 115 F (46 C).

Units are tested and certified by ARI and certified by UL and CSA. Factory-run test printout included in each rooftop.

24-volt control circuit, with resettable breaker.

Two-inch disposable-type return air filters in dedicated rack.

Hermetic compressor on independent circuit with internal line break and overload protection, self-lubricating with internal discharge muffler.

Scroll compressor with internal overload protection (TF/TM007, TM012, TF014).

Refrigerant circuit contains a filter drier to trap dirt and particles.

Single compressor on 3 to 6 ton units.

Dual compressors on 71/2 to 121/2 ton units.

Two-speed direct drive evaporator fan on all units except 007 size which is belt driven. Adjustable belt drive fans are optional on all sizes.

Non-corrosive condensate pan with self-draining sloping design with both bottom and side drain connections.

Thru-the-bottom power control and gas entry capability.

Indoor and outdoor coils constructed of aluminum fins mechanically bonded to seamless copper tubes.

Single point electrical and gas connections.

Direct drive propeller condenser fan totally enclosed with permanently lubricated bearings.

Pre-painted, insulated cabinet with primer inner panels, certified 500-hr salt spray test and non-corrosive screws.

Dedicated L,M,N 3 to 5 ton “Low NOx” units that meet California air quality refrigerant of 40 nanograms/joule or less.

Large, easily removable panels provide ready access to unit components for rapid removal or maintenance.

Filter access door for filter access and maintenance that requires no tools.

Induced draft (negative pressure) combustion system with Hall effect sensor to detect proper operation of induced draft motor.

All units have single stage cooling and single stage heating capability. High heat models have 2-stage heating capability.

Heavy Alumagard™ coated heat exchangers, with aluminized steel burners.

Heating controls with direct spark ignition and redundant gas valve. Fan switch, high temperature limit switch and flame rollout switch standard.

Fixed orifice metering device precisely controls refrigerant flow to each circuit individually.

Reliable accurate control circuit with color coded wires and easy acces- sible terminal board.

Integrated gas control board with built-in diagnostics to determine error codes and control indoor fan on/off delays.

Integrated gas control board provides anti-cycle protection for gas heat operation.

Loss of charge (low pressure), freeze protection, and high pressure switches standard.

Refrigerant filter drier/circuit.

PERFORMANCE DATA

COOLING

Net Total Cap.___________________________________________ Btuh

Net Sensible Cap. ________________________________________ Btuh

Compressor Power Input ___________________________________ kW

_________________________________________ F Outdoor Air Temp.

Indoor Entering Air

db _____________ F

wb _______________ F

CFM __________

Ext. Static Pressure___________________ in. wg

Fan RPM _______________________________________________ Bhp

SEER/EER _________________________________________________

HEATING

Input:

Stage 1 ___________________ Total______________

Btuh

Output:

Stage 1 ____________________ Total______________

Btuh

AFUE _______________________________ kW_________________%

Steady State _______________________________________________%

Operating Weight _______________ lbs. (unit)_____________ lbs. (curb)

ELECTRICAL DATA

Power Supply to Unit ________________ Volts ________________ Phase _________________________ Hz

Minimum Circuit Amps ______________ Maximum Overcurrent Protection (Fuse Only) _______________

FACTORY-INSTALLED

FIELD-INSTALLED ACCESSORIES

OPTIONS

Durablade Economizer — Fully Modulating EconoMi$er with Controller Copper/Copper Coils — Evaporator, Condenser, Both

Pre-Coated Condenser Coil E-Coat (Post-Coated) Condenser Coil Non-Fused Disconnect Switch 115-Volt Convenience Outlet Apollo Communicating Control PremierLink™ Control

25% Manual Air Damper

Alternate Motor and Drive (except 007 and 009 size)

￿High-Static Motor (except 014)

EconoMi$er with 4-20 mA Actuator, Less Controller

Durablade Economizer — Fully Modulating EconoMi$er

25% Open Two-Position Damper

25% Open Manual Air Damper

100% Open Two-Position Damper Solid-State Enthalpy Control Differential Enthalpy Control Roof Curb (14- or 24-in. Height)

Thru-the-Bottom/Roof Curb Electrical and Gas Connection Kit

Time Guard® II Compressor Anti-Cycle Control

Condenser Coil Hail Guard

￿Room Temperature Sensor PremierLink™ Control

Condenser Coil Protector (004-007)

EconoMi$er/Power Exhaust

–20 F Motormaster® Low Ambient Control

Kit

Programmable Set-Back Thermostat

Electrical Mechanical Thermostat & Subbase

Liquid Propane (LP) Gas Kit

Flue Hood Protector Kit

Flue Discharge Deflector

Indoor Fan/filter Status Indicator

￿62AQ Energy$Recycler

Other ____________________

2

Page 2
Image 2