UNIT OPERATION HAZARD

If you have difficulty locating your air filter(s) or have questions concerning proper filter maintenance, contact your dealer for instructions. When replacing filters, always use the same size and type of filter that was supplied originally by the installer.

!CAUTION

UNIT OPERATION HAZARD

Failure to follow this caution may result in property damage.

Never operate your unit without filters in place. An accumulation of dust and lint on internal parts of your unit can cause loss of efficiency and blower motor and/or compressor damage.

FILTER

ACCESS

PANEL

Filter Access Panel

For Accessory Filter Rack

Access Panels

A09044

Fig. 3 - Unit Access Panel

RETURNFig. 3 - Unit Access Panelfilter access)Fig. 4 - Small Chassis Filter AccessFig. 5 - Large Chassis Filter AccessSmall Chassis (See Fig. 4)Large Chassis (See Fig. 5)Table 2 – Indoor Air Filter Data with EconomizerManual backgroundManual backgroundManual background DUCT COVER Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background (Remove for Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

filter access)

SMALL CHASSIS

A10063

Fig. 4 - Small Chassis Filter Access

LARGE CHASSIS

A10062

Fig. 5 - Large Chassis Filter Access

Replacing or inspecting filters in units with econom- izers

Small Chassis (See Fig. 4)

1.Remove return air duct cover at rear of unit using a 5/16-in. nut driver.

2.Remove the filter(s) by pulling it out and through the unit duct opening. If filter is dirty, replace both filters with new ones.

When installing the new filters, note the direction of the airflow arrows on the filter frame, which should be pointing at the indoor coil.

3.Reinstall duct cover ensuring opening is air and water tight.

Large Chassis (See Fig. 5)

1.Remove filter access door using a 5/16-in. nut driver.

2.Remove the filter(s) by pulling it out and through the unit filter access door. If filter is dirty, replace both filters with new ones.

Units with bent indoor coils, install 24 x 18 x 1 (610 x 457 x 25 mm) filter first and then install 24 x 16 x 1 (610 x 406 x 25) filter.

When installing the new filters, note the direction of the airflow arrows on the filter frame, which should be pointing at the indoor coil.

3.Reinstall filter access door ensuring opening is air and watertight.

Table 2 – Indoor Air Filter Data with Economizer

 

 

Unit Size

Filter Size

30-36

2 each 20 x 12 x 1

(508 x 305 x 25 mm)

 

42-48

1 each 24 x 14 x 1 (610 x 356 x 25 mm),

24 x 16 x 1 (610 x 406 x 25 mm)

 

60*

1 each 24 x 16 x 1 (610 x 406 x 25 mm),

24 x 18 x 1 (610 x 457 x 25 mm)

 

*Units with bent indoor coil.

Fans and Fan Motors

Periodically check the condition of fan wheels and housings and fan-motor shaft bearings. Contact your dealer for the required annual maintenance.