Neveroperate your unit without the filter(s) in place. Failure to heed this warning may result in damage to the blower motor and/or compressor. An accumulation of dust and lint on internal parts of your unit can cause loss of efficiency and , in some cases, a fire.

Fans and Fan Motor

Periodically, check the condition of fan wheels and housings and fan-motor shaft bearings. Contact your dealer for the required annual maintenance.

Indoor and Outdoor Coils

Cleaning of the coils should only be done by qualified service personnel. Contact your dealer for the required annual mainte- nance.

Condensate Drain

The drain pan and condensate drain line should be checked and cleaned at the same time the cooling coils are checked by your dealer.

Compressor

All compressors are factory-shipped with a normal charge of the correct type refrigeration grade oil. A compressor should rarely require additional oil.

Condenser Fan

Do not poke sticks, screwdrivers, or any other objects into revolving fan blades. Injury or equipment damage may result.

The fan must be kept free of all obstructions to ensure proper cooling. Contact your dealer for any required service.

Electrical Controls and Wiring

Electrical controls are difficult to check without proper instrumen- tations. If there are any discrepancies in the operating cycle, contact your dealer and request service.

Refrigerant Circuit

The refrigerant circuit is difficult to check for leaks without the proper equipment. If inadequate cooling is suspected, contact your local dealer for service.

System under pressure. Relieve pressure and recover all refrigerant before system repair or final unit disposal to avoid serious injury or death. Use all service ports and open all flow-control devices, including solenoid valves.

Unit Panels

After performing any maintenance or service on either of these units, be sure all panels are fastened securely in place to prevent rain from entering unit cabinet and to prevent disruption of the correct unit airflow pattern.

REGULAR DEALER MAINTENANCE

In addition to the type of routine maintenance you might be willing to perform, your unit should be inspected regularly by a properly trained service technician. An inspection (preferably each year, but at least every other year) should include the following:

1.Inspection and, if required, cleaning of the outdoor and indoor coils.

2.Inspection and, if required, cleaning of the indoor coil drain pan.

3.Inspection and cleaning of blower wheel housing and motor.

4.Inspection of all supply-air and return-air ducts for leaks, obstructions, and insulation integrity. Any problems found should be resolved at this time.

5.Inspection of the unit base to ensure that no cracks, gaps, etc., exist which may cause a hazardous condition.

6.Inspection of the unit casing for signs of deterioration.

7.Inspection of all electrical wiring and components to assure proper connection.

8.Inspection for leaks in the refrigerant circuit. Pressure-check to determine appropriate refrigerant charge.

9.Inspection of compressor oil level by service person to ensure proper oil level is maintained in the compressor when it is installed and running.

10.Operational check of the unit to determine working condi- tions. Repair or adjustment should be made at this time.

Your servicing dealer may offer an economical service contract that covers seasonal inspections. Ask for further details.

Complete service instructions can be found in each unit's Instal- lation, Start-Up and Service Instructions.

BEFORE YOU CALL FOR SERVICE ...

...check for several easily-solved problems.

If insufficient heating or cooling is suspected:

( ) Check for sufficient airflow. Check the air filter for dirt. Check for blocked return-air or supply-air grilles. Be sure they are open and unobstructed. If these checks do not reveal the cause, call your servicing dealer.

If your unit is not operating at all, check the following list for easy solutions:

( ) Check to be sure that your thermostat temperature selector is set below the indoor temperature during the cooling season or above the indoor temperature during heating season. Be sure the SYS- TEM switch or MODE control is in the COOL or HEAT position and not in the OFF position.

( ) If your unit still fails to operate, call your servicing dealer for troubleshooting and repairs. Specify the model and serial numbers of your unit. (Record them in this manual in the space provided.) If the dealer knows exactly which unit you have, he may be able to offer suggestions over the phone, or save valuable time through knowledgeable preparation for the service call.

IN CASE OF TROUBLE

If you perform the steps above and unit performance is still unsatisfactory, shut off the unit and call your dealer.

Dealer's Name ______________________________________

Telephone___________________________________________

Unit Model__________________________________________

Unit Serial Number___________________________________

3

Page 3
Image 3
Carrier 50JZ Regular Dealer Maintenance, Before YOU Call for Service, If insufficient heating or cooling is suspected

50JZ specifications

The Carrier 50JZ is a modern chiller that exemplifies high efficiency and innovative technology, aimed at providing effective cooling solutions for a variety of applications. Designed for commercial and industrial use, the 50JZ unit is particularly well-suited for large buildings, data centers, and manufacturing facilities, where reliable temperature control is crucial.

One of the standout features of the Carrier 50JZ is its high energy efficiency, which not only helps in reducing operational costs but also aligns with contemporary sustainability goals. The chiller is equipped with advanced inverter technology that modulates the compressor speed, allowing it to adjust to varying cooling demands efficiently. This results in significant energy savings, especially during partial load conditions.

The 50JZ utilizes environmentally friendly refrigerants, further contributing to its appeal in today's eco-conscious market. The use of R-134a refrigerant minimizes harmful effects on the ozone layer and meets stringent environmental regulations, ensuring compliance with global standards.

Another notable characteristic of the 50JZ is its compact design, which facilitates easy installation and maintenance. The unit is designed for space optimization, allowing it to fit into tight environments while still delivering powerful performance. Additionally, its robust construction ensures durability and longevity, making it a reliable choice for long-term operations.

In terms of technology, the 50JZ features Carrier's proprietary controls system, which provides advanced monitoring and management capabilities. This system allows for real-time performance tracking and diagnostics, enabling facility managers to optimize operations and respond swiftly to any operational issues. The integration of IoT capabilities offers enhanced connectivity, enabling remote access to system performance data for improved decision-making.

Noise reduction is another critical aspect of the Carrier 50JZ. It incorporates innovative sound attenuation technologies, resulting in quieter operation compared to traditional chillers. This makes it ideal for noise-sensitive environments such as schools, hospitals, and residential areas.

Overall, the Carrier 50JZ combines high efficiency, eco-friendliness, advanced technology, and user-centric design, making it a top choice for effective cooling in various applications. With its ability to deliver reliable performance while minimizing environmental impact, the Carrier 50JZ represents the future of cooling solutions in industrial and commercial settings.