IMPORTANT FACTS

Your furnace must have adequate airflow for efficient combustion and safe ventilation. Do not enclose it in an airtight room or “seal” it behind solid doors.

To minimize the possibility of serious personal injury, fire, furnace damage, or improper operation, carefully

follow these safety rules:

FOR YOUR SAFETY

Do not store or use gasoline or other flam- mable vapors and liquids in the vicinity of this or any other appliance.

SAFETY CONSIDERATIONS

Installing and servicing of heating equipment can be hazardous due to oil and electrical components. Only trained and qualified personnel should install, repair, or service heating equipment.

Untrained personnel can perform basic maintenance functions such as cleaning and replacing air filters. All other operations must be performed by trained service personnel. Observe safety precautions in this manual, on tags, and on labels attached to the furnace and other safety precautions that may apply.

Recognize safety information. This is the safety-alert symbol ! . When you see this symbol on the furnace and in instructions or manuals, be alert to the potential for personal injury.

Understand the signal words — DANGER, WARN- ING, and CAUTION. These words are used with the safety-alert symbol. DANGER identifies the most seri- ous hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which may result in minor per- sonal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability or operation.

3

Do not cover the furnace, store trash or debris near it, or in any way block the flow of fresh air to the unit.

Combustion air must be clean and not contaminated with chlorine or fluorine. These compounds are present in many products around the home, such as: water soft- ener salts, laundry bleaches, detergents, adhesives, paints, varnishes, paint strippers, waxes, and plastics.

Make sure the combustion air for your furnace does not contain any of these compounds. During remodel- ing be sure the combustion air is fresh and uncontam- inated. If air with vapors of these compounds is burned in your furnace, the heat exchangers and metal vent system may deteriorate.

NOTE: Do not use this furnace if any part has been under water. Immediately call a qualified service tech- nician to inspect the furnace and to replace any part of the control system, electrical components, and any oil control which has been under water.

NOTE: The qualified installer or agency must use only factory-authorized replacement parts, kits, and acces- sories when servicing this product.

The furnace burner control has a safety device which must be manually reset. If the furnace is left unattended for an extended period of time, have it checked period- ically for proper operation. This precaution will prevent problems associated with no heat, such as frozen water pipes, etc.

!WARNING

FIRE, EXPLOSION, CARBON MONOXIDE POI- SONING HAZARD

Failure to follow this warning could lead to sooting, fire, explosion, and/or severe bodily harm.

For use with grade 2 Fuel Oil maximum. Do not use gasoline, crankcase oil, or any oil con- taining gasoline!

!CAUTION

FIRE AND UNIT OVERHEAT HAZARD

Failure to follow this caution may result in mi- nor personal or property damage.

Never burn garbage or paper in the heating system and never leave rags, paper, or any flammable items around the unit.

STARTING YOUR FURNACE

This appliance is equipped with an ignition device which automatically lights the burner each time the thermostat starts your furnace. Follow these important safeguards:

!CAUTION

FIRE AND EXPLOSION HAZARD

Failure to follow this caution may result in mi- nor personal or property damage.

This furnace is equipped with a constant type primary ignition system. DO NOT ATTEMPT TO LIGHT WITH A MATCH.

4

Page 4
Image 4
Carrier 58CLA manual Important Facts, Safety Considerations, Starting Your Furnace, For Your Safety

58CLA specifications

The Carrier 58CLA is a high-efficiency gas furnace known for its advanced technology and reliable performance. Designed to provide exceptional heating and comfort for residential spaces, the 58CLA stands out as a premium choice for homeowners seeking energy efficiency and durability.

One of the defining features of the Carrier 58CLA is its two-stage heating operation. This allows the furnace to operate at a low stage for most of the heating demands, enhancing comfort while consuming less energy. During peak demand periods, the furnace seamlessly transitions to a higher stage, providing optimal warmth without compromising efficiency. This ability to adjust its output based on the heating needs of the home ensures consistent temperatures, reduces energy bills, and increases comfort.

The furnace is equipped with an advanced, ECM (Electronically Commutated Motor) blower motor, which significantly improves airflow consistency and reduces electrical consumption compared to traditional motors. This technology not only enhances efficiency but also contributes to quieter operation. Homeowners will appreciate the reduced noise levels, making the 58CLA a great choice for living environments.

Additionally, the Carrier 58CLA incorporates a durable heat exchanger designed for long-lasting performance. Made of aluminized steel, the heat exchanger ensures efficient heat transfer and reliability over time. Carrier also includes a rust-resistant finish, which protects the furnace from corrosion, enhancing its lifespan.

In terms of installation flexibility, the 58CLA is designed to accommodate various home configurations. It offers both horizontal and vertical venting options, making it compatible with different spaces and layouts. Moreover, the unit's compact design allows for easy placement in smaller mechanical rooms or tight spaces.

Another noteworthy feature is its compatibility with Carrier's Infinity Touch Control, which allows homeowners to have advanced control over their heating system. This smart thermostat can regulate not only the furnace but also integrates with other HVAC components for a comprehensive home comfort solution.

Overall, the Carrier 58CLA gas furnace represents a fusion of efficiency, comfort, and innovative technology. With its two-stage heating, advanced blower motor, durable construction, and installation flexibility, it remains a top choice for those looking to enhance their home's heating system. Whether faced with the chill of winter or maintaining a cozy indoor environment, homeowners can trust the Carrier 58CLA to deliver reliable heating performance year after year.