Carrier A10247 owner manual Slide Side Filter Out of Furnace

Models: A10247

1 10
Download 10 pages 21.26 Kb
Page 7
Image 7
Fig. 16 - Slide Side Filter Out of Furnace

A00227

Fig. 16 - Slide Side Filter Out of Furnace

A00228

Fig. 17 - Slide Bottom Filter Out of Furnace

4. Inspect the filter. If torn, replace it.

NOTE: If a washable filter has been replaced with:

a. Factory specified disposable media filter -- Do not clean. If dirty, replace only with media filter having the same part number and size. Install with airflow direction arrow pointing towards blower.

b. Electronic Air Cleaner (EAC) -- Refer to EAC

Owner's Manual for maintenance information.

5.Wash filter (if dirty) in sink, bathtub, or outside with a garden hose. Always use cold tap water. A mild liquid de- tergent may be used if necessary. Spray water through filter in the opposite direction of airflow. Allow filter to dry.

6.Reinstall clean air filter.

7.Replace filter cabinet door. (See Fig. 18 and 19.)

8.Turn on electrical supply to furnace (See Fig. 11).

A06192

Fig. 18 - Replace Side Filter Cabinet Door

A06193

Fig. 19 - Replace Bottom Filter Cabinet Door

NOTE: If side return ducts are used, 2 filters may be required in

some models. The procedure listed above may be used to remove side filters.

PERSONAL INJURY HAZARD

Failure to follow this caution may result in personal iniury.

Use care when cutting support rods in filters to protect against flying pieces and sharp rod ends. Wear safety glasses, gloves,

and appropriate protective clothing.

Filters may be field modified by cutting filter material and support

rods (3) in filters. Alternate sizes and additional filters may be ordered from your dealer.

 

 

(1)

16x25

(1)

14x25

6/4"

(19

mm)

thick

washable

or

14-1/2

(368)

4-5/16"

(110

mm)

thick

 

(406

x 635)

(356

x 635)

 

 

 

media-type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/4"

(19

mm)

thick

washable

or

17-1/2

(445)

(1)

16 x 25

(1)

16 x 25

4-5/16"

(110

mm)

thick

 

media-type

 

 

 

 

 

 

(406

x 635)

(406

x 635)

 

 

 

 

21

(566)

(1)

16 x 25

(1)

20 x 25

3/4"

(19

mm)

thick

washable

 

 

 

(406

x 665)

(508

x 665)

or 4-5/16"

(100 mm) thick

 

 

 

 

 

 

 

media-type

 

 

 

 

24

(610)

(1)

16 x 25

(1)

24 x 25

6/4"

(19

mm)

thick

washable

or

 

 

(406

x 665)

(610

x 665)

4-5/16"

(100

mm)

thick

 

 

 

 

 

 

 

media-type

 

 

 

 

*Recommended

**Some furnaces may have 2 filters

Page 7
Image 7