Carrier ASPBS1CCA016, ASPBA1CCA016 manual Home Standby - 16kW, Generator, Engine

Models: ASPBS1CCA016 ASPBA1CCA016

1 4
Download 4 pages 40.88 Kb
Page 3
Image 3
Home Standby - 16kW
Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046 and DIN6271). * Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feet above sea level; and also will decrease about 1 percent for each 12° C (10° F) above 15.5° C (60°F).
Engine Start Sequence
-Manual/Test (start) ......................................................................................................................
-Off ............................................................................................................................................
Automatic Start on Utility failure
7 day exerciser
Stops unit. Power is removed Control and charger still operate Start with starter control, unit stays on. If utility fails, transfer to load takes place.
Cyclic cranking: 7 sec. on, 7 rest
(90 sec. maximum duration)
Engine Warm-up ..................................................................................................................................................... 10 seconds
Engine Cool-Down ..................................................................................................................................................... 1 minute
Starter Lock-out ........................................................................................................................................ Starter cannot re-engage until
5 sec. after engine has stopped.
2.5 Amp Timed Trickle Battery Charger .................................................................................................................. Standard
Automatic Voltage Regulator w/Overvoltage Protection ............................................................................................ Standard
Automatic Low Oil Pressure Shutdown ..................................................................................................................... Standard
Overspeed Shutdown ............................................................................................................................................ Standard, 72Hz
High Temperature Shutdown ..................................................................................................................................... Standard
Overcrank Protection ................................................................................................................................................. Standard
Safety Fuse ............................................................................................................................................................... Standard
Mode Switch
-Auto ...............................................................................................................................................
Required fuel pressure to generator fuel inlet at all load ranges - 5 to 7 inches of water column for natural gas, 10 to 12 inches of water column for LP gas
CONTROLS

Home Standby - 16kW

 

GENERATOR

Model ASPBS1CCA016 - Steel, Model ASPBA1CCA016 - Aluminum

Rated Maximum Continuous Power Capacity (LP)

16,000 Watts*

Rated Maximum Continuous Power Capacity (NG)

15,000 Watts*

Rated Voltage

120/240

Rated Maximum Continuous Load Current

 

120 Volts

133.3 LP/125 NG

240 Volts

66.6 LP/62.5 NG

Main Line Circuit Breaker

65 Amp

Phase

1

Number of Rotor Poles

2

Rated AC Frequency

60Hz

Power Factor

1

Battery Requirement (not included)

Group 26, 12 Volt Netgative Ground and 525 Cold-cranking Amperes Minimum

Unit Weight

445 lbs. (Steel), 414 lbs. (Alum)

Dimensions (L” x W” x H”)

48 x 24 x 28-1/4

Sound output in dB(A) at 23 ft. with generator operating at full load

71.5

Sound output in dB(A) at 23 ft. with generator in Ultra Quiet exercise mode

59

ENGINE

Model ASPBS1CCA016 - Steel, Model ASPBA1CCA016 - Aluminum

Type of Engine

OHVI V-TWIN

Number of Cylinders

2

Rated Horsepower

30 @ 3,600 rpm

Displacement

992cc

Cylinder Block

Aluminum w/Cast Iron Sleeve

Valve Arrangement

Overhead Valve

Ignition System

Solid-state w/Magneto

Governor System

Electronic

Compression Ratio

9.5:1

Starter

12Vdc

Oil Capacity Including Filter

Approx. 1.7 Qts.

Standby Operating RPM

3,600

Exercise RPM

2400

Fuel Consumption

 

Natural Gas cu.ft./hr.

 

........................................1/2 Load

173

........................................Full Load

245

Liquid Propane ft3/hr (gal/hr)

 

........................................1/2 Load

59 (1.59)

........................................Full Load

92 (2.51)

Page 3
Image 3
Carrier ASPBS1CCA016, ASPBA1CCA016 manual Home Standby - 16kW, Generator, Engine