48/50HG014-028 Single-Package Rooftop Units Accessory Return and Supply Smoke Detectors

Installation Instructions

Part No. CRSMKDET001C00 and CRSMKSUP001A00

CONTENTS

GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . 1

INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5

Check Package Contents. . . . . . . . . . . . . . . . . . . . . . . . . 2

Return Air Smoke Detector Installation. . . . . . . . . . . 2

Supply Air Smoke Detector Installation . . . . . . . . . . 5

Configuring the ComfortLink™ Controller. . . . . . . . 5

OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5,6

MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Cleaning Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Filter Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Board Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

TROUBLESHOOTING. . . . . . . . . . . . . . . . . . . . . . . . . . . .7,8

Smoke Entry Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

AIRFLOW TEST

SMOKE RESPONSE TEST

Standby, Alarm and Sensitivity Tests. . . . . . . . . . . . . 8

STANDBY AND TROUBLE TEST

ALARM TESTS

SENSITIVITY TEST

GENERAL

An HVAC (heating, ventilation and air-conditioning) sys- tem supplies conditioned air to virtually every area of a building. Smoke introduced into this air duct system will be distributed throughout the entire building. Smoke detectors designed for use inside the unit are used to sense the presence of smoke passing through the unit.

The smoke detector utilizes photoelectric technology for the detection of smoke. This detection method, when combined with an efficient ducting design, samples air passing through the unit. If sufficient smoke is sensed, an alarm signal is initiat- ed and the ComfortLink controls will shut down the unit. With the unit shut down, the unit will not blow toxic smoke and fire gases throughout the areas served by the duct system.

The return air smoke detector is part number CRSMKDET001C00. The supply air smoke detector is part number CRSMKSUP001A00.

SAFETY CONSIDERATIONS

Installation and servicing of air-conditioning equipment can be hazardous due to system pressure and electrical compo- nents. Only trained and qualified service personnel should install, repair, or service air-conditioning equipment.

Untrained personnel can perform the basic maintenance functions of cleaning coils and filters and replacing filters. All other operations should be performed by trained service per- sonnel. When working on air-conditioning equipment, observe precautions in the literature, tags and labels attached to the unit, and other safety precautions that may apply.

Follow all safety codes. Wear safety glasses and work gloves. Use care when handling and installing the accessory.

Before performing service or maintenance operations on unit, turn off main power switch to unit. Electrical shock could cause personal injury.

The National Fire Protection Association has established that DUCT DETECTORS MUST NOT BE USED AS A SUBSTITUTE FOR OPEN AREA DETECTOR PRO- TECTION as a means of providing life safety. Nor are they a substitute for early warning in a building’s regular fire detection system. Carrier supports this position and strongly recommends that the user read NFPA Standards 90A, 72, and 101. This smoke detector is listed per UL 268A.

This device will not operate without electrical power. Fire situations may cause an interruption of power. The system safeguards should be discussed with your local fire protection specialist.

This device will not sense smoke unless the ventilation sys- tem is operating and the cover is installed.

For this detector to function properly, it MUST be installed according to the instructions in this manual. Furthermore, the detector MUST be operated within ALL electrical and environmental specifications listed in this manual. Failure to comply with these requirements may prevent the detec- tor from activating when smoke is present in the air duct.

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Book

1

1

4

4

PC 111

Catalog No. 534-80096

Printed in U.S.A.

Form 48/50HG-19SI

Pg 1

2-02

Replaces: 48/50HG-17SI

Tab

1a

1b

6a

6b

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 1
Image 1
Carrier CRSMKDET001C00, CRSMKSUP001A00 installation instructions Contents, General, Safety Considerations

CRSMKDET001C00, CRSMKSUP001A00 specifications

Carrier has a long-standing reputation for producing high-quality HVAC systems, and the CRSMKSUP001A00 and CRSMKDET001C00 models exemplify this commitment to excellence. These units are designed to meet the evolving demands of today’s commercial and residential environments, offering both efficiency and advanced technology.

The CRSMKSUP001A00, also known as the support unit, is engineered to provide reliable heating and cooling solutions. A key feature of this model is its compact design, which allows it to fit easily into a variety of spaces, making it an ideal choice for installations where space is limited. This unit incorporates advanced refrigerant technology, promoting an optimal operating environment while minimizing energy consumption. Additionally, the unit is equipped with smart diagnostic capabilities, allowing for easy maintenance and troubleshooting.

In terms of efficiency, the CRSMKSUP001A00 boasts high SEER and HSPF ratings, which are crucial for reducing energy costs while maintaining comfort throughout the changing seasons. Its environmentally friendly refrigerants further enhance its appeal to consumers and businesses focused on sustainability.

On the other hand, the CRSMKDET001C00 serves as the detachable unit within this system. This model is built with flexibility in mind, allowing for easy integration with existing HVAC systems. The CRSMKDET001C00 features plug-and-play installation, meaning that it can be set up with minimal downtime, making it a convenient option for busy commercial environments.

This unit is equipped with advanced control technologies, including Wi-Fi connectivity, which enables users to monitor and manage their HVAC systems remotely. Such features are vital for businesses looking to optimize their operational efficiency and reduce energy expenses. Furthermore, the CRSMKDET001C00 employs variable-speed technology, allowing for precise temperature control and enhancing overall comfort by adjusting to the distinct needs of the space.

Both models exemplify Carrier's focus on reliable performance and energy efficiency. With high-quality components and innovative technology, they deliver effective and customizable climate control solutions for a wide range of applications. The CRSMKSUP001A00 and CRSMKDET001C00 are ideal choices for those looking for advanced, efficient, and user-friendly HVAC solutions. Carrier's commitment to technological advancements and sustainable practices positions these models as top contenders in the HVAC market, ensuring climate control that is both effective and environmentally responsible.