| Part 4 | USEFUL INFORMATION | |||
1. |
| Troubleshooting |
|
|
| |
|
|
| Symptom/Problem |
| Most common causes | Solutions |
|
|
|
|
|
|
|
| 1 |
| E01 appears on the display. |
| Changing modes without complet- | Return mode switch to where it stops buzz- |
|
|
| ing transaction. | ing and press p. | ||
|
|
|
|
| ||
| 2 |
| E08 appears on the display. |
| Sign on operation is not performed. | Prior to starting registration of any other |
|
|
|
|
|
| operation, press Z~<and then :. |
|
|
|
|
|
| Remove jammed paper. Turn Mode switch |
| 3 |
| E94 appears on the display. |
| Printer paper is jammed. | to OFF then turn to ON, or Turn power OFF |
|
|
|
|
|
| and then turn power ON. |
| 4 |
| No date on receipt. |
| Printer is programmed as a journal. | Program printer to print receipts. |
|
| Paper is not advancing enough. | ||||
|
|
|
|
| ||
| 5 |
| Drawer opens up after ringing up | Department is programmed as a | Program the dept. as a normal dept. | |
|
| only one time. |
| single item dept. | ||
|
|
|
|
| ||
| 6 |
| Not clearing totals at end of day | Using X mode to take out reports. | Use Z mode to take out reports. | |
|
|
| after taking report. |
|
|
|
|
|
| Programming is lost whenever |
|
|
|
| 7 |
| register is unplugged or there is | Bad or no batteries. | Put in new batteries and program again. | |
|
|
| a power outage. |
|
|
|
| 8 |
| Register is inoperative. |
| No power. | Pull lever underneath register at rear. |
|
| Can’t get money out of drawer. | ||||
|
|
|
|
|
Note: If you cannot resolve your difficulty, please feel free to call your dealer or
2.Specifications
INPUT METHODEntry:
Display (LED): Amount 8 digits (zero suppression); Department/PLU No.; No. of repeats
PRINTER |
|
Journal: | 14 digits (Amount 10 digits, Symbol 3 digits) |
(or Receipt) | Automatic paper roll winding (journal) |
Paper roll: | 58 mm ⋅ 80 mm ∅ (Max.) |
Entry 8 digits; Registration 7 digits; Total 8 digits
CALCULATOR FUNCTION8 digits; Arithmetic calculations; Percent calculations
Memory protection batteries:
The effective service life of the memory protection batteries 3
Power source/Power consumption: | See the rating plate. | |
Operating temperature: 32°F to 104°F (0°C to 40°C) | ||
Humidity: | 10 to 90% |
|
Dimensions: | 7 3/8"(H)⋅13"(W)⋅14 3/16"(D) with S drawer | |
| (188 mm(H)⋅330 mm(W)⋅360 mm(D)) | |
Weight: | 9 lbs (4 kg) with S drawer |
E
36