Operation Guide 3189/3252

Countdown Timer

Press D while a countdown operation is in progress to pause it. Press D again to

resume the countdown.
Hours Seconds

Minutes

The countdown timer can be set within a range of one minute to 24 hours. An alarm sounds when the countdown reaches zero.

The countdown operation continues even if you exit the Countdown Timer Mode.

All of the operations in this section are performed in the Countdown Timer Mode, which you enter by pressing C (page E-5).

To use the countdown timer

Press D while in the Countdown Timer Mode to start the countdown timer.

When the end of the countdown is reached, the alarm sounds for 10 seconds or until you stop it by pressing any button. The countdown time is reset to its starting value automatically after the alarm stops.

To stop a countdown operation completely, first pause it (by pressing D), and then

press B. This returns the countdown time to its starting value.

To set the countdown start time

1. In the Countdown Timer Mode, hold down A until the hours of the countdown start time start to flash, which indicates the setting screen.

2. Press C to move the flashing between the hours and minutes.3. While a setting is flashing, use D (+) or B (–) to change it.To set the starting value of the countdown time to 24 hours, set 0:00.4.Press A to exit the setting screen.
E-30

E-31

 

 

Reference

This section contains more detailed and technical information about watch operation. It also contains important precautions and notes about the various features and functions of this watch.

Holding down C to turn the button operation tone on or off also causes the watch’s current mode to change.

The mute indicator is displayed in all modes when the button operation tone is turned off.

Button Operation Tone
Mute indicatorE-32

The button operation tone sounds any time you press one of the watch’s buttons. You can turn the button operation tone on or off as desired.

Even if you turn off the button operation tone, the alarm, Hourly Time Signal, and Countdown Timer Mode alarm all operate normally.

To turn the button operation tone on and off

In any mode (except when a setting screen is on the display), hold down C for about three seconds to toggle the button operation tone on (mute indicator not displayed) and off (mute indicator displayed).

Scrolling

The B and D buttons are used in various modes and setting screens to scroll through data on the display. In most cases, holding down these buttons during a scroll operation scrolls at high speed.

Initial Screens

When you enter the World Time or Alarm Mode, the data you were viewing when you last exited the mode appears first.

E-33
World Time

The seconds count of the World Time is synchronized with the seconds count of the Timekeeping Mode.

All World Time Mode times are calculated from the current Home City time in the Timekeeping Mode using UTC time offset values.

The UTC offset is a value that indicates the time difference between a reference point in Greenwich, England and the time zone where a city is located.

The letters “UTC” is the abbreviation for “Coordinated Universal Time”, which is the world-wide scientific standard of timekeeping. It is based upon carefully maintained atomic (cesium) clocks that keep time accurately to within microseconds. Leap seconds are added or subtracted as necessary to keep UTC in sync with the Earth’s rotation.

E-34

Specifications

Accuracy at normal temperature: ±30 seconds a month

Timekeeping: Hour, minutes, seconds, a.m. (A)/p.m. (P), day, day of the week, month, year

Time system: Switchable between 12-hour and 24-hour formats

Calendar system: Full auto-calendar pre-programmed from the year 2000 to 2099 Standard time/Daylight saving time

Other: Home City code (can be assigned one of 30 city codes); Daylight Saving Time (summer time)/Standard Time

Data Bank: 25 records (8-character name, 12-digit number)World Time: 30 cities (29 time zones)Other: Daylight Saving Time/Standard Time

Day Counter

Number of days between current date and a target dateMemory capacity: 5 counters (8-character text, target date (year, month, day))Target date setting range: January 1, 1950 to December 31, 2049E-35

Other: Day counter alarm (DAYS indicator flashes on the display when a target date is reached regardless of year.)

Alarm: 5 Daily Alarms, Hourly Time Signal

Stopwatch

Measuring unit: 1/100 of a secondMeasuring capacity: 23 hours, 59 minutes, 59.99 secondsFunctions: Elapsed time, split time and two finishes

Countdown Timer

Measuring unit: 1 second

Input range: 1 minute to 24 hours (1-minute increments and 1-hour increments) Other: EL backlight, Button operation tone on/off

Battery: One lithium battery (Type: CR1616)
Battery life
3 years under the following conditions2 seconds of backlight operation per day10 seconds of alarm operation per dayE-36

City Code Table

L-1

City Code Table

 

 

 

 

 

• Based on data as of July 2010.

 

 

 

 

 

 

 

• The rules governing global times (UTC offset and GMT differential) and summer time are

City

City

UTC Offset/

 

City

City

UTC Offset/

determined by each individual country.

Code

GMT Differential

 

Code

GMT Differential

* In December 2007, Venezuela changed its offset from –4 to –4.5. Note, however, that

 

 

 

PPG

PAGO PAGO

–11

 

JED

JEDDAH

+3

this watch displays an offset of –4 (the old offset) for the CCS (Caracas, Venezuela) city

HNL

HONOLULU

–10

 

THR

TEHRAN

+3.5

code.

ANC

ANCHORAGE

–9

 

DXB

DUBAI

+4

 

LAX

LOS ANGELES

–8

 

KBL

KABUL

+4.5

 

DEN

DENVER

–7

 

KHI

KARACHI

+5

 

CHI

CHICAGO

–6

 

DEL

DELHI

+5.5

 

NYC

NEW YORK

–5

 

DAC

DHAKA

+6

 

CCS*

CARACAS

–4

 

RGN

YANGON

+6.5

 

YYT

ST. JOHNS

–3.5

 

BKK

BANGKOK

+7

 

RIO

RIO DE JANEIRO

–3

 

HKG

HONG KONG

+8

 

RAI

PRAIA

–1

 

TYO

TOKYO

+9

 

LON

LONDON

0

 

ADL

ADELAIDE

+9.5

 

PAR

PARIS

+1

 

SYD

SYDNEY

+10

 

CAI

CAIRO

+2

 

NOU

NOUMEA

+11

 

JRS

JERUSALEM

 

WLG

WELLINGTON

+12

 

 

 

 

L-2L-3