Operation Guide 3772

Stopwatch

Minutes

Seconds

1/100 second

The stopwatch lets you measure elapsed time, split times, and two finishes.

The display range of the stopwatch is 59 minutes, 59.99 seconds.

The stopwatch continues to run, restarting from zero after it reaches its limit, until you stop it.

Exiting the Stopwatch Mode while a split time is frozen on the display clears the split time and returns to elapsed time measurement.

The stopwatch measurement operation continues even if you exit the Stopwatch Mode.

All of the operations in this section are performed in the Stopwatch Mode, which you enter by pressing C.

To turn the Daily alarm and the Hourly Time Signal on and off

In the Alarm Mode, press D to cycle through the settings shown below.

Alarm On Indicator / Hourly Time Signal On Indicator

 

Alarm Off

 

Alarm On

 

Alarm Off

 

Alarm On

 

 

Signal Off

 

Signal Off

 

Signal On

 

Signal On

 

 

 

 

 

 

 

 

 

To measure times with the stopwatch

 

 

Elapsed Time

 

 

 

 

D

D

D

D

A

Start

Stop

Re-start

Stop

Clear

Split Time

 

 

 

 

D

A

A

D

A

Start

Split

Split release

Stop

Clear

Two Finishes

 

 

 

 

D

A

D

A

A

Start

Split

Stop

Split release

Clear

 

First runner

Second runner

Display time of

 

 

finishes.

finishes.

second runner.

 

 

Display time of

 

 

 

 

first runner.

 

 

 

Countdown Timer

Minutes

You can set the countdown timer within a range of one to

60 minutes. An alarm sounds when the countdown

Seconds

reaches zero.

 

Calibration signal reception (both auto and manual) is

 

disabled while a countdown timer operation is in

 

progress.

 

All of the operations in this section are performed in the

 

Countdown Timer Mode, which you enter by pressing

 

C.

To set the countdown start time

1.While the countdown start time is on the display in the Countdown Timer Mode, hold down A until the current countdown start time starts to flash, which indicates the setting screen.

If the countdown start time is not displayed, use the procedure under “To use the countdown timer” to display it.

2.While a setting is flashing, use D(+) and B(–) to change it.

3.Press Ato exit the setting screen.

To use the countdown timer

Press Dwhile in the Countdown Timer Mode to start the countdown timer.

When the end of the countdown is reached, the alarm sounds for 10 seconds or until you stop it by pressing any button. The countdown time is automatically reset to its starting value after the alarm stops.

Press Dwhile a countdown operation is in progress to pause it. Press Dagain to resume the countdown.

To completely stop a countdown operation, first pause it (by pressing D), and then press A. This returns the countdown time to its starting value.

Alarm

Alarm time

When the alarm is turned on, the alarm sounds when the

(Hour : Minutes)

alarm time is reached. You can also turn on an Hourly

PM indicator

 

Time Signal, which will cause the watch to beep twice

 

 

 

every hour on the hour.

 

 

 

All of the operations in this section are performed in the

 

 

 

Alarm Mode, which you enter by pressing C.

 

 

 

Hourly time signal on indicator

Alarm on indicator

To set the alarm time

1.In the Alarm Mode, hold down A until the hour setting of the alarm time starts to flash, which indicates the setting screen.

This operation automatically turns on the alarm.

2.Press Cto move the flashing between the hour and minute settings.

3.While a setting is flashing, use D(+) and B(–) to change it.

When setting the alarm time using the 12-hour format, take care to set the time correctly as a.m. (no indicator) or p.m. (P indicator).

4.Press Ato exit the setting screen.

Alarm Operation

The alarm sounds at the preset time for about 10 seconds, regardless of the mode the watch is in.

To stop the alarm tone after it starts to sound, press any button.

To test the alarm

In the Alarm Mode, hold down Dto sound the alarm.

The alarm on indicator and the Hourly Time Signal on indicator are shown on the display in all modes while these functions are turned on.

Illumination

An LED (light-emitting diode) and light guide panel illuminate the digital display for easy reading in the dark.

See “Illumination Precautions” for other important information.

To turn on illumination

In any mode, press B to illuminate the display.

You can specify 1.5 seconds or 2.5 seconds as the illumination duration. See “To set the current digital time and date manually” for more information.

Timekeeping

Use the Timekeeping Mode to set and view the current time and date. This section also explains how to manually set the current date and time.

When setting the time, you can also configure settings for the illumination duration and the 12/24-hour format.

All of the operations in this section are performed in the Timekeeping Mode, which you can enter by pressing C.

Press A.

PM indicator

 

Hour : Minutes

 

A

 

 

Reception date

Press D.

Reception time

Last Signal

Screen

Setting the Digital Time and Date Manually

Make sure you select your Home City code before you change the current time and date settings. World Time Mode times are all displayed in accordance with the Timekeeping Mode settings. Because of this, World Time Mode times will not be correct if you do not select the proper Home City code before setting the time and date in the Timekeeping Mode.

To set the current digital time and date manually

 

 

 

 

 

1. In the Timekeeping Mode, hold down A until the city

 

code starts to flash, which indicates the setting screen.

 

2. Press Cto move the flashing in the sequence shown

 

 

 

 

 

 

below to select other settings.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

City code

 

 

 

 

 

City Code

DST

12/24-Hour

Seconds

Hour

 

Format

 

 

 

 

 

 

 

 

 

Day

Month

 

Year

Minutes

3.When the setting you want to change is flashing, use B and/or Dto change it as described below.

Screen:

To do this:

Do this:

 

Change the city code

Use D (east) and B (west).

 

 

 

 

Cycle between Daylight Saving Time

Press D.

 

(ON), Standard Time (OFF), and

 

 

Auto DST (A t )

 

 

Toggle between 12-hour (12H) and

Press D.

 

24-hour (24H) timekeeping

 

 

Reset the seconds to 00

Press D.

 

Toggle the illumination duration

Press B.

 

setting between 1.5 seconds ( ) and

 

 

2.5 seconds ( )

 

 

 

 

 

Change the hour or minutes

Use D (+) and B (–).

Change the year

Change the month or day

See “City Code Table” for a complete list of available city codes.

For information about settings other than the time and date, see the following.

Illumination duration: Illumination

3