Operation Guide 5334
Indicators and Crown Operation
Stopwatch
| Stopwatch Second Hand |
| Minute Hand |
| Click 1 |
Hour Hand | Click 2 |
| |
Second Hand | |
| |
| Crown |
Stopwatch Minute Hand | Day Indicator |
| |
Stopwatch functions |
|
|
Setting the Current Time and Day
To adjust the time setting
1.When the second hand is at 12 o’clock, pull the Crown out to Click 2.
2.Rotate the Crown to change the time setting.
3.Push the Crown back in.
Note
ξTake care that you set the correct AM or PM time.
ξWhen changing the time, move the minute hand four or fi ve minutes past your fi nal setting, and then back it up to the setting you want.
To change the day indicator setting
1.Pull the Crown out to Click 1.
2.Rotate the Crown away from you to set the day.
3.Push the Crown back in.
Note
ξThe day indicator setting uses a
ξAvoid changing the day indicator setting between the hours of 9 p.m. and 1 a.m. Otherwise, the day indicator may not change correctly at midnight.
Using the Stopwatch
The stopwatch measures elapsed time in
Elapsed time |
|
|
|
|
|
|
| |
A |
| A |
| A |
| A |
| B |
|
|
|
| |||||
Start | Stop | Stop | Reset | |||||
Split time |
|
|
|
|
|
|
| |
A |
| B |
| B |
| A |
| B |
Start | Split | Split release | Stop | Reset |
Two finishes |
|
|
|
|
|
|
| |
A |
| B |
| A |
| B |
| B |
Start | Split | Stop | Split release | Reset | ||||
|
| First runner | Second runner | Display time of |
| |||
|
| fi nishes. | fi nishes. | second runner. |
| |||
|
| Display time of |
|
|
|
|
| |
|
| fi rst runner. |
|
|
|
|
|
Note
ξThe Stopwatch Hands move for only the fi rst 60 minutes of an elapsed time operation. After that, they stop at the 12 o’clock position.
ξThe stopwatch will not operate while the second hand is jumping at
ξIf a low charge state (indicated by the second hand jumping at
Important!
ξDo not operate the stopwatch with the crown pulled out.
Correcting the 0 Positions of the Stopwatch Hands
Perform the following procedure if the stopwatch hands do not return to their 0 (zero) positions when you reset the stopwatch.
1.Pull the Crown out to Click 2.
2.Hold down A for about two seconds, the Stopwatch
ξ If the hand does not align with 12 o’clock, use the B button to adjust it.
ξHolding down B moves the current hand at high speed.
3.Hold down A for about two seconds, the Stopwatch Second Hand will rotate to indicate the second hand setting mode.
ξIf the hand does not align with 12 o’clock, use the B button to adjust it.
ξHolding down B moves the current hand at high speed.
4.Hold down A for about two seconds, the Stopwatch Minute Hand will rotate to indicate the minute hand setting mode.
ξIf the hand does not align with 12 o’clock, use the B button to adjust it.
ξHolding down B moves the current hand at high speed.
5.After all of the hands are the way you want, push the Crown back in.
Abnormal Hand Movement or Function
Should the watch ever exhibit abnormal hand movement or function, or if the second hand does not move normally
1.Pull the Crown out to Click 2.
2.Hold down both A and B for about two seconds.
3.Push the Crown back in.
ξThe second hand will start to move.
ξIf the second hand is jumping at
Important!
ξTimekeeping stops while the crown is pulled out. Correct the current time setting after performing the above operation.
4.If the Stopwatch Hands do not return to their 0 (zero) positions when you reset the stopwatch, correct their 0 positions (page
|
|
Important!
ξTimekeeping stops while the crown is pulled out. Correct the current time setting after performing the above operation.
Reference
ξTo adjust the time setting (page
ξTo change the day indicator setting (page
Specifications
Accuracy: ±20 seconds average per month
Stopwatch: Measuring Capacity: 59'59.95" (60 minutes) Measuring Unit: 1/20 second
Measurements: Elapsed time; split time; two fi nishes
Other: Low battery alert
Power Supply: Solar panel and one rechargeable battery
Approximate battery operating time: 5 months (no exposure to light after a full charge)