Operation Guide 5369 (MTG)
1. In the Countdown Timer Mode, pull out the crown to the fi rst click.
ξIf you do not perform any operation with the crown for about two minutes
|
|
|
|
|
|
|
|
|
| after pulling it out, crown operations will become disabled and the watch | ||
|
|
|
|
|
|
|
|
|
| hands will no longer move when you rotate the crown. If this happens, | ||
|
|
|
|
|
|
|
|
|
| push the crown back in and then pull it out again. | ||
|
|
|
|
|
|
|
|
| 2. Rotate the crown to set the countdown start time. | |||
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
| ξ You can use | ||
|
|
|
|
|
|
|
| step. |
| |||
|
|
|
|
|
|
|
|
|
| ξ To set a start time of 60 minutes, position the n Small Hour Hand at | ||
|
|
|
|
|
|
|
|
|
| 12 o’clock and the m Small Hour Hand | ||
|
|
|
|
|
|
|
|
|
| a start time of 120 minutes, position the n Small Hour Hand and the | ||
|
|
|
|
|
|
|
|
|
| m Small Hour Hand | ||
|
|
|
|
|
|
|
|
| 3. Push the crown back in. |
| ||
To perform a countdown timer operation |
| |||||||||||
A |
|
|
|
|
|
|
|
|
| A |
| B |
|
|
|
|
|
|
|
|
|
| |||
Start |
|
| Stop | Reset |
ξPressing Bwhile the Countdown Timer is stopped resets the displayed time to the start time specified by you.
ξPressing Bwill not perform a reset while the hands are moving to the current timer time after you enter the Countdown Timer Mode.
Using the Alarm
When the alarm is turned on, an alarm will sound for about 10 seconds each day when the current time kept by the watch reaches the preset alarm time. This is true even if the watch is not in the Alarm Mode.
|
|
|
| Hand Functions |
|
|
|
| z Hour Hand |
|
|
|
| |
|
|
|
| x Second Hand |
|
|
|
| c Minute Hand |
|
|
|
| |
|
|
|
| v Hour Hand |
|
|
|
| |
|
|
|
| |
|
|
|
| b Small Minute Hand: Indicates the currently set alarm time minute. |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
| n Small Hour Hand: Indicates the currently set alarm time hour. | ||
|
| m Small Hour Hand | ||
|
|
|
| |
|
|
|
| hour format. |
,Lower Dial Hand: Indicates the current alarm ON/OFF setting.
To enter the Alarm ModeRefer to the Mode Reference Guide (page
ξEntering the Alarm Mode will cause the , Lower Dial Hand to move to ON or OFF.
5. Push the crown back in.
ξThe alarm always works based on the time kept by the watch.
To turn the alarm on or offIn the Alarm Mode, press Ato toggle the alarm between on and off. The , Lower Dial Hand will indicate the current ON/OFF setting.
To stop the alarmPress any button.
For full details, see the procedure from page
Pull crown out to second click.
B(Until x Second Hand indicates 12 o’clock)
x Second Hand | C | C | |||||
c Minute Hand |
| . Day Indicator |
|
|
| b Small Minute Hand | |
|
|
| |||||
z Hour Hand |
|
|
|
|
|
| C |
|
|
|
|
|
| ||
|
|
|
|
|
|
| |
Auto Adjustment |
| , Lower Dial Hand |
|
| n Small Hour Hand | ||
|
|
|
|
C
Manual Adjustment
ξAfter completing adjustment, push the crown back in. Pushing the crown back in part way through
adjustment will return to the mode you started from with any adjustments you made in effect.
ξBefore starting a countdown timer operation, check to make sure that the countdown timer is not already operating (indicated by a moving b Small Minute Hand). If it is, press Ato stop it and then B to reset to the countdown start time.
ξPulling out the crown while a countdown operation is in progress will stop the ongoing operation so you can change the countdown start time setting.
To stop the alarm
Press any button.
1.In the Alarm Mode, pull out the crown to the fi rst click.
ξIf you do not perform any operation with the crown for about two minutes after pulling it out, crown operations will become disabled and the watch hands will no longer move when you rotate the crown. If this happens, push the crown back in and then pull it out again.
2.Rotate the crown to set the alarm time minute.
ξA
3.Press C.
ξThis causes the n Small Hour Hand to move.
4.Rotate the crown to set the alarm time hour.
ξMovement of the m Small Hour Hand
ξThe 12 o’clock position of the m Small Hour Hand
Note
ξEach press of the Cbutton toggles between the alarm time minute setting and the hour setting.
C
MinuteHour
ξSelecting the minute setting causes the b Small Minute Hand to move slightly. Selecting the hour setting causes the n Small Hour Hand to move slightly.
Adjusting the Hand and Day Home Positions
If the watch is exposed to strong magnetism or impact, it can cause its hands and/or the date to go out of alignment. This can result in incorrect date and/or time indication even though a time calibration signal is being received.
The watch automatically adjusts the x Second Hand, c Minute Hand, and z Hour Hand positions periodically. You also can trigger hand position adjustment manually, if you want.
ξThe v Hour Hand
If you notice that the b Small Minute Hand, n Small Hour Hand, m Small Hour Hand
ξThe m Small Hour Hand
Important!
ξYou do not need to perform the procedure in this section if the watch is indicating the time and/or day correctly.
1.In any mode, pull the crown out to the second click.
2.Hold down Buntil the watch beeps and the x Second Hand moves to 12 o’clock. This takes about fi ve seconds.
|
|
|
|
|
|
|
| ξ Release Bwhen the x Second Hand gets to 12 o’clock. At this |
|
|
|
|
|
|
|
| time the watch will start automatic adjustment of the x Second |
|
|
|
|
|
|
|
| Hand, c Minute Hand, and z Hour Hand positions. |
|
|
|
|
| ||||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| ||
|
|
|
|
| ||||
|
|
|
|
|
|
|
| ξ Adjustment is complete when the x Second Hand, c Minute |
|
|
|
|
|
|
| Hand, and z Hour Hand move to 12 o’clock. |
3.Press C.
ξThis will cause the z Hour Hand and . Day Indicator to move.
ξWait until the . Day Indicator stops at a position halfway between 31 and 1.
ξIf the . Day Indicator is not halfway between 31 and 1, rotate the crown until it is.
ξRotating the crown causes the z Hour Hand to move in 12- hour increments, and the . Day Indicator to move in