Cateye CC-RD200 manual Operating the computer Measuring screen, Troubleshooting, Specification

Models: CC-RD200

1 2
Download 2 pages 28.1 Kb
Page 2
Image 2
Operating the computer [Measuring screen]

Operating the computer [Measuring screen]

Tm Elapsed Time

 

Pace arrow

 

 

Indicates whether the current

0:00’00” - 9:59’59”

 

speed is faster ( ) or slower ( )

 

 

than the average speed.

C Cadence

 

Current speed

 

0(20) - 299 rpm

 

0.0(4.0) - 200.0 km

 

 

[0.0(3.0) - 125.0 mph]

CC-RD200

Troubleshooting

MODE does not work when the computer is mounted on its bracket.

Check that there is no dirt between the bracket and the computer.

Wash off the bracket with water to get rid of any dirt, and to ensure that the computer slides in and out smoothly.

Speed (Cadence) are not displayed. (Touch a metal item against two contact points of

The contacts to be short-

the computer several times to create a short circuit while observing the display. If a

circuited intermittently are

numeric value appears, this signifies that the computer is functioning normally.)

located on the back.

Is the clearance between the sensor and magnet too great? (must be 3 mm)

 

Does the magnet pass through the sensor line?

 

Adjust the positions of the magnet and sensor.

 

 

 

 

 

Dst Trip Distance

 

 

 

 

0.00 - 999.99 km [mile]

 

 

 

 

Dst 2 Trip Distance-2

 

 

 

 

0.00 - 999.99 /

 

 

 

 

1000.0 - 9999.9 km [mile]

MODE

Av Average Speed*2

*1

 

 

0.0 - 200.0 km/h

 

 

 

 

[0.0 - 125.0 mph]

 

 

 

 

Mx Maximum Speed

 

 

 

 

0.0(4.0) - 200.0 km/h

 

 

 

 

[0.0(3.0) - 125.0 mph]

 

 

 

 

Odo Total Distance

 

 

 

 

0.0 - 9999.9 /

 

 

 

 

10000 - 99999 km [mile]

 

 

 

 

Clock

 

 

 

 

0:00 - 23:59

 

 

 

 

or 1:00 - 12:59

*1

With the computer installed on the bracket,

 

 

press on the three raised dots on the face of

 

 

the computer.

 

*2

If Tm exceeds approximately 27 hours or

 

 

DST exceeds 999.99 km, .E (Error) is

 

 

displayed as the average speed. Reset data.

Selected Mode

Starting/Stopping measurement

Measurements occur automatically when the bicycle is in use. During

measurement, or flashes.

Switching computer function

Pressing MODE switches function, in order, as shown on the left.

Resetting data

To reset measurement data, display any data other than for Dst-2and then press and hold MODE. Pressing and holding MODE with Dst-2displayed resets Dst-2only.

The total distance is never reset.

Power-saving function

If the computer has not received any signal for an hour, power- saving mode will activate and only the clock will be displayed.

Alternatively, if the sensor detects a signal or MODE is pressed, the main display reappears.

Speed Cadence

Is there any foreign matter (which would prevent a clean contact) on the contact points of the computer and/or bracket?

Clean the contact points.

Check that no wire cable is worn or broken. Even with a normal appearance, it may be that a wire cable could be broken internally. Replace the bracket sensor set.

No display.

Is battery in the computer run down?

Replace it. Then reinitialize the computer referring to “Preparing the computer”.

Incorrect data appear.

Reinitialize the computer referring to “Preparing the computer”.

Specification

Battery

Lithium battery (CR1620) x 1

Battery life

Approx. 2 years (Using the battery one hour a day; the battery life will vary with the

 

conditions of use.)

Controller

4-bite, 1-chip microcomputer (Crystal controlled oscillator)

Display

Liquid crystal display

Sensor

No contact magnetic sensor

Wheel circumference range

0100 mm - 3999 mm (Default figure A: 2096 mm, B: 2096 mm)

Working temperature

32 °F - 104 °F (0 °C - 40 °C) (This product will not function appropriately when exceeding the

 

Working Temperature range. Slow response or black LCD at lower or higher temperature

 

may happen respectively.)

Dimensions/weight

1-53/64” x 1-7/32” x 19/32” (46.5 x 31 x 15 mm) / 0.63 oz (18 g)

*The factory-loaded battery life might be shorter than the above-mentioned specification.

*The specifications and design are subject to change without notice.

 

 

Standard Parts

 

#160-2090

#160-0280

#160-2093

#169-9766

Parts kit

Braket band

Braket/Sensor

Cadence magnet

Changing the computer settings [menu screen]

To bring up the menu screen, press MENU in any mode. Each time MODE is CC-RD200 pressed, the relevant menu screen appears. Pressing and holding MODE MENU changes the setting of the displayed menu.Troubleshooting

MODE

MODE

 

MODE

MODE

MODE

 

Wheel

Wheel size entry

Clock setting

Total distance

Speed unit

selection

 

 

 

 

manual entry

 

 

Setting

 

 

 

 

 

 

change (by

*

After changing, be sure to press MENU to register the setting.

 

* If the menu screen is not touched for a minute, the Measuring

 

pressing &

MODE

 

screen reappears without data changes.

 

 

holding)

 

 

 

 

 

 

 

 

 

 

 

Wheel selection ..... Toggle between the specified wheel size (tire circumference)

and

. Use this function if the computer is to be shared

between two bicycles.

and

.

Pressing MODE toggles between

Wheel size entry .... Pressing MODE increases the value, and pressing and

holding MODE moves to the next digit.

*To enter the wheel size Starting/Stopping measurement , display Switching computer functionusing “Wheel selection”. Clock setting .......... To set the clock, refer to “Preparing the computer-4”.

Total distance manual entry

................................ Before reinitializing the computer, note the total distance. This

 

reading will later allow you to enter the total distance

 

manually. Pressing MODE increases the value, and pressing

 

and holding MODE moves to the next digit.

 

Speed unit

Pressing MODE toggles between

and

.

Maintenance

To clean the computer or accessories, use diluted neutral detergent on a soft cloth, and wipe it off with a dry cloth.

Replacing the battery

If the display appears faded, replace the battery.

 

 

Install a new lithium battery (CR1620) with the (+)

Close

 

side facing upward. Then reinitialize the computer

 

 

referring to “Preparing the computer”.

Open

CR1620

 

 

#169-9691

#169-6180

Lithium battery

Wheel magnet

(CR1620)

 

LIMITED WARRANTY

2-Year Computer only

(Accessories/Bracket sensor and Battery Consumption excluded)

CatEye cycle computers are warranted to be free of defects from materials and workmanship for a period of two years from original purchase. If the product fails to work due to normal use, CatEye will repair or replace the defect at no charge. Service must be performed by CatEye or an authorized retailer.

To return the product, pack it carefully and enclose the warranty certificate (proof or purchase) with instruction for repair. Please write or type your name and address clearly on the warranty certificate.

Insurance, handling and transportation charges to CatEye shall be borne by person desiring service.

For UK and REPUBLIC OF IRELAND consumers, please return to the place of purchase. This does not affect your statutory rights.

CO.,LTD.

2-8-25, Kuwazu, Higashi Sumiyoshi-ku, Osaka 546-0041 Japan Attn: CATEYE Customer Service Section

Service & Research Address for USA CATEYE Service and Research Center

1705 14th St. 115 Boulder, CO 80302 Phone: 303.443.4595

Toll Free: 800.5CATEYE

Fax: 303.473.0006

E-mail: service@cateye.com

URL: http://www.cateye.com

Page 2
Image 2
Cateye CC-RD200 manual Operating the computer Measuring screen, Troubleshooting, Specification, Maintenance, Resetting data