CDA HCE340 manual Electrical Plates And Vitroceramic Cooking Hobs, 8a, 9a, 9b

Models: HCE340

1 21
Download 21 pages 57.56 Kb
Page 14
Image 14
ELECTRICAL PLATES AND VITROCERAMIC COOKING HOBS

ELECTRICAL PLATES AND VITROCERAMIC COOKING HOBS

288

 

 

510

 

 

288

 

510

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

 

 

 

50

 

 

 

 

 

50

 

 

 

 

 

 

 

 

 

 

 

 

490

+

 

 

 

 

490

+0

 

0

 

 

 

 

 

 

+

 

0

 

 

0

2

 

2

 

 

 

 

 

 

 

 

+

 

 

 

 

2

 

 

2

 

270

 

 

 

 

 

270

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 6.8a

Fig. 6.8b

 

TECHNICAL INFORMATION FOR THE INSTALLER

Before installing the cooktop, remove the protective film.

These cooking hobs are designed to be embedded into kitchen fixtures measuring 600 mm in depth and from 20 to 40 mm thick, for 2 electrical plates hob, and from 30 to 40 mm thick for vitroceramic hob.

In order to install the cooker top into the kitchen fixture, a hole with the dimensions shown in figs. 6.8a and 6.8b has to be made, keeping in consideration the following:

within the fixture, between the bottom side of the cooker top and the upper surface of any other appliance or internal shelf there must be a clearance of at least 30 mm;

the cooker top must be kept no less than 50 mm away from any side wall;

the cooker top must be kept at a distance of no less than 50 mm from the rear wall.

there must be a distance of at least 650 mm between the hob and any wall cupboard or extractor hood positioned immedi- ately above (see figs. 6.9a and 6.9b).

the coatings of the walls of the unit or appliances near the cooktop must be heat resistant ("Y" protection against heat- ing in compliance with standards EN 60335-2-6).

Do not instal the appliance near inflammable materials (eg. curtains).

mm

650 mm

450

 

50

mm

 

Fig. 6.9a

450 mm

650 mm

50

mm

 

Fig. 6.9b

33

Page 14
Image 14
CDA HCE340 manual Electrical Plates And Vitroceramic Cooking Hobs, Technical Information For The Installer, 8a, 9a, 9b