Electricity supply to your oven

Electricity supply to your oven

Warning! this appliance must be earthed.

This appliance must be connected by a competent person, using fixed wiring via a double pole switched fused spur outlet.

We recommend that the appliance is connected by a qualified electrician, who is a member of the N.I.C.E.I.C. and who will comply with the I.E.E and local regulations. The wires in the mains lead are coloured in accordance with the following code:

GREEN AND YELLOW = EARTH BLUE = NEUTRAL BROWN = LIVE.

As the colours of the wires in the mains lead for the appliance, may not correspond with the coloured markings identifying the terminals in your spur box, proceed as follows:

1.The wire which is coloured green and yellow must be connected to the terminal marked E (Earth) or coloured Green.

2.The wire which is coloured blue must be connected to the terminal marked N (Neutral), or coloured Black.

3.The wire which is coloured brown must be connected to the terminal marked L (Live), or coloured Red.

DOUBLE POLE SWITCHED

FUSE SPUR OUTLET

USE A 13 AMP FUSE