CDA SV430 manual Warning! This appliance must be earthed, Mains Electricity Connection

Models: SV430

1 16
Download 16 pages 60.74 Kb
Page 15
Image 15
Mains Electricity Connection

Mains Electricity Connection

Warning! This appliance must be earthed

We recommend that the appliance is connected by a qualified electrician, who is a member of the N.I.C.E.I.C. and who will comply with the I.E.E. and local regulations.

This appliance is intended to be connected to fixed wiring and is not suitable for connection to a 13A plug or 13A supply.

This appliance is intended to be connected to fixed wiring by a double pole switch, having a contact separation of at least 3mm in all poles. The switch must be positioned no further than 2m from the appliance.

This appliance is supplied with a 3 core mains cable; the wires are in accordance with the following code:

Green and Yellow = Earth Blue = Neutral

Brown = Live

Please note:

Blue Warning! This appliance must be earthed

Brown

Fig. 15 N L

Green/yellow

The mains cable must only be replaced by a qualified electrician or service engineer and must be of equivalent or better rating (i.e. 1.5mm2, HO5V2V2-F).

The marking of the current rating of the fuse or circuit breaker protecting this appliance should be marked on the socket outlet (16A).

Assembly and electrical connection should be carried out by specialised personnel.

When installing this product we recommend you seek the help of another individual.

The mains isolation switch must be accessible after installation.